Аннотация

BACKGROUND

Speckle tracking imaging is a promising new echocardiographic method to assess left ventricular (LV) mechanical dyssynchrony. Our aim was to assess a new speckle tracking regional strain algorithm by comparison with angle-corrected tissue Doppler (TD) in an animal model of left bundle branch block and cardiac resynchronization therapy.

METHODS AND

RESULTS

Ten open-chest dogs had routine gray-scale and TD images of the mid-LV short-axis plane. Electrical activation was altered by pacing from right ventricular, LV free wall, and biventricular sites to create various degrees of mechanical dyssynchrony and alter regional function. Segmental time to peak strain, peak strain, and frame-by-frame strain were measured by angle-corrected TD, TD M-mode, and speckle tracking on the same digital cineloop. Of 240 possible paired TD and speckle tracking segments, data were available for 222 segments (93%); images with catheter artifacts were prospectively excluded. Comparative overall time to peak strain by each method correlated well: r = 0.96, bias = -6 +/- 20 ms. Of 80 possible paired M-mode TD and speckle tracking segments, strain data were available for 76 segments (95%). Comparative overall time to peak strain, peak strain, and frame-by-frame strain analysis in 1012 frames by each method correlated well: r = 0.98, bias of 1 +/- 14 ms; r = 0.82, bias of 3% +/- 7%; and r = 0.91, bias of 0% +/- 6%, respectively.

CONCLUSION

Regional strain analysis using echocardiographic speckle tracking radial strain strongly correlated with strain by angle-corrected TD imaging in an animal model of dyssynchrony. Speckle tracking radial strain has potential for clinical applications.

Для цитирования: Tanabe Masaki, Lamia Bouchra, Tanaka Hidekazu, Schwartzman David, Pinsky Michael R, Gorcsan John. Echocardiographic speckle tracking radial strain imaging to assess ventricular dyssynchrony in a pacing model of resynchronization therapy.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2008. DOI: 10.1016/j.echo.2008.09.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.