MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2004.10.074

Медицинская библиотека · Journal of the American College of Cardiology · 2005

Outcomes with the paclitaxel-eluting stent in patients with acute coronary syndromes: analysis from the TAXUS-IV trial.

Moses Jeffrey W, Mehran Roxana, Nikolsky Eugenia, Lasala John M, Corey Woodrow, Albin Glenn, Hirsch Cary, Leon Martin B, Russell Mary E, Ellis Stephen G, Stone Gregg W

Клиническое исследованиеКлиническое исследование IV фазыСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

We sought to investigate the outcomes of paclitaxel-eluting stent implantation in patients with unstable angina or non-ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention (PCI).

BACKGROUND

Whether the paclitaxel-eluting stent is safe and effective in patients with acute coronary syndromes (ACS) is unknown.

METHODS

In the TAXUS-IV trial, 1,314 patients with stable or unstable ischemic syndromes undergoing PCI were randomized to treatment with either the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). The results were stratified by the acuity of the presenting clinical syndrome.

RESULTS

Acute coronary syndromes were present in 450 patients (34.2%), 237 of whom were assigned to paclitaxel-eluting stents and 213 to bare-metal stents. The baseline and procedural characteristics were well matched between the groups. Clinical outcomes at 30 days were similar with both stents. At one-year follow-up, patients with ACS assigned to the paclitaxel-eluting stent compared to the control stent had strikingly lower rates of target lesion revascularization (TLR) (3.9% vs. 16.0%, p < 0.0001) and major adverse cardiac events (11.1 vs. 21.7%, p = 0.002). By multivariate analysis, ACS was an independent predictor of in-stent restenosis in the cohort treated with bare-metal stents (hazard ratio [HR] = 2.03 [95% confidence interval (CI) 1.05 to 3.92], p = 0.035), while among patients randomized to the paclitaxel-eluting stents, ACS was an independent predictor of freedom from restenosis (HR = 0.27 [95% CI 0.08 to 0.97], p = 0.04).

CONCLUSIONS

The use of the paclitaxel-eluting TAXUS stent was safe in patients with unstable ischemic syndromes, and was associated with marked reduction of ischemia-driven TLR and adverse cardiac events at one year.

Для цитирования: Moses Jeffrey W, Mehran Roxana, Nikolsky Eugenia, Lasala John M, Corey Woodrow, Albin Glenn, Hirsch Cary, Leon Martin B, Russell Mary E, Ellis Stephen G, Stone Gregg W. Outcomes with the paclitaxel-eluting stent in patients with acute coronary syndromes: analysis from the TAXUS-IV trial.. Journal of the American College of Cardiology. 2005. DOI: 10.1016/j.jacc.2004.10.074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.