MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joic.12326

Медицинская библиотека · Journal of interventional cardiology · 2016

The Learning Curve for Transcatheter Mitral Valve Repair With MitraClip.

Eleid Mackram F, Reeder Guy S, Malouf Joseph F, Lennon Ryan J, Pislaru Sorin V, Nkomo Vuyisille T, Rihal Charanjit S

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to assess the learning curve for TMVR for treatment of primary mitral regurgitation (MR).

BACKGROUND

Data are lacking regarding the technical experience required to achieve optimal clinical outcomes with transcatheter mitral valve repair (TMVR) using the edge-to-edge MitraClip technique.

METHODS

We examined the sequential experience of the first 75 patients (age 80 ± 9 years; 77% male) who underwent TMVR at our institution. A sequence number of each patient was assigned as a continuous variable and in tertiles for analysis.

RESULTS

TMVR with MitraClip was successful in 97% with an average procedural time of 106 ± 39 minutes. The 30-day rate of major adverse cardiovascular events was 7%. With increased case experience, there were decreases in procedural time, fluoroscopy time, length of hospital stay, and major adverse cardiovascular events. Procedural success, residual mitral regurgitation and NYHA functional classification at 30-day follow-up remained unchanged throughout the experience.

CONCLUSIONS

The learning curve for TMVR with MitraClip for treatment of primary MR is characterized by a sequential reduction in procedure time, fluoroscopy time, procedural complications, and hospital length of stay at a tertiary academic medical center. Thirty-day procedural results are favorable and similar during the initial learning period.

Для цитирования: Eleid Mackram F, Reeder Guy S, Malouf Joseph F, Lennon Ryan J, Pislaru Sorin V, Nkomo Vuyisille T, Rihal Charanjit S. The Learning Curve for Transcatheter Mitral Valve Repair With MitraClip.. Journal of interventional cardiology. 2016. DOI: 10.1111/joic.12326.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.