MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.atherosclerosis.2014.11.002

Медицинская библиотека · Atherosclerosis · 2014

Permanent polymer of drug eluting stents increases eosinophil cationic protein levels following percutaneous coronary intervention independently of C-reactive protein.

Niccoli Giampaolo, Calvieri Camilla, Minelli Silvia, Copponi Giorgia, Montone Rocco A, Imaeva Asiya, Roberto Marco, Cosentino Nicola, Crea Filippo

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To assess eosinophil cationic protein (ECP) and C-reactive protein (CRP) serum levels at three time points according to different stent types.

METHODS

54 patients (age 64 ± 10 years, male 78%), undergoing Bare Metal Stent (BMS) (n = 11), mammalian Target Of Rapamycin (mTOR)-inhibitor DES (n = 27) and mTOR-inhibitor bioabsorbable DES (BES) (n = 16) implantation for stable angina (SA) or non-ST-elevation acute coronary syndromes (NSTE-ACS), were prospectively enrolled. ECP and CRP serum levels were assessed before revascularization, at 1-month and at 1-year after the procedure. Moreover, 21 patients found to have inducible ischemia or angina symptoms at 6 month-stress test underwent 1-year follow-up (FU) angiography.

RESULTS

Baseline and 1-month ECP levels were similar among the 3 groups, whilst 1-year ECP was significantly higher in m-TOR-DES [8.61 (6.55-19.77) μg/ml] compared with m-TOR-BES [2.03 (1.78-5.53) μg/ml] and BMS-treated patients [2.23 (1.45-8.95) μg/ml] (p = 0.02), without significant difference between BES and BMS. CRP was similar among the 3 groups at all time points. 1-year ECP significantly correlated with late loss in patients undergoing FU angiography (r = 0.64, p = 0.002), while CRP did not (p = NS).

CONCLUSIONS

Our finding suggests that mTOR-DES stent type is associated with an increase of ECP levels at 1-year, possibly reflecting a persistent eosinophil activation triggered by permanent polymer.

Для цитирования: Niccoli Giampaolo, Calvieri Camilla, Minelli Silvia, Copponi Giorgia, Montone Rocco A, Imaeva Asiya, Roberto Marco, Cosentino Nicola, Crea Filippo. Permanent polymer of drug eluting stents increases eosinophil cationic protein levels following percutaneous coronary intervention independently of C-reactive protein.. Atherosclerosis. 2014. DOI: 10.1016/j.atherosclerosis.2014.11.002.