Atherosclerosis · 2014
Circulating soluble LR11, a novel marker of smooth muscle cell proliferation, is enhanced after coronary stenting in response to vascular injury.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ogita Manabu, Miyauchi Katsumi, Jiang Meizi, Kasai Takatoshi, Tsuboi Shuta, Naito Ryo, Konishi Hirokazu, Dohi Tomotaka, Yokoyama Takayuki, Okazaki Shinya, Shimada Kazunori, Bujo Hideaki, Daida Hiroyuki
Аннотация
OBJECTIVE: Restenosis after vascular intervention remains a major clinical problem. Circulating LR11 has been shown a novel marker of intimal smooth muscle cell (SMC) proliferation in human and animal studies. The present study was performed to clarify the clinical significance of circulating LR11 in patients with stable angina pectoris after coronary stenting.
METHODS AND RESULTS: We firstly investigated the circulating sLR11 levels for 28 days after arterial injury in mice, and then assessed time-dependent change in circulating sLR11 level after coronary stenting in a clinical study. Mouse sLR11 levels rapidly increased to 4.0-fold of the control value without cuff placement at postoperative day (POD) 14, and the levels gradually declined to 3.1-fold of the control value until POD 28 in mice. The circulating soluble LR11 levels were measured (before and at 14, 60 and 240 days after coronary stenting in a clinical study of 102 consecutive patients with stable angina pectoris who were treated with percutaneous coronary intervention. Circulating sLR11 levels were significantly increased on days 14 and 60 after the procedure and positively associated with the angiographic late loss index.
CONCLUSIONS: Our study suggested that circulating sLR11 levels may be a potential marker for angiographic late loss in patients after coronary stenting. Further mechanistic studies are expected to know the clinical significance of sLR11 as a novel marker for intimal SMC.
METHODS AND RESULTS: We firstly investigated the circulating sLR11 levels for 28 days after arterial injury in mice, and then assessed time-dependent change in circulating sLR11 level after coronary stenting in a clinical study. Mouse sLR11 levels rapidly increased to 4.0-fold of the control value without cuff placement at postoperative day (POD) 14, and the levels gradually declined to 3.1-fold of the control value until POD 28 in mice. The circulating soluble LR11 levels were measured (before and at 14, 60 and 240 days after coronary stenting in a clinical study of 102 consecutive patients with stable angina pectoris who were treated with percutaneous coronary intervention. Circulating sLR11 levels were significantly increased on days 14 and 60 after the procedure and positively associated with the angiographic late loss index.
CONCLUSIONS: Our study suggested that circulating sLR11 levels may be a potential marker for angiographic late loss in patients after coronary stenting. Further mechanistic studies are expected to know the clinical significance of sLR11 as a novel marker for intimal SMC.
Предметные рубрики MeSH
AgedAngina PectorisAngiographyAnimalsBiomarkersCell ProliferationCoronary RestenosisFemaleFemoral ArteryHumansLDL-Receptor Related ProteinsMaleMembrane Transport ProteinsMiceMiddle AgedMyocytes, Smooth MusclePercutaneous Coronary InterventionPostoperative PeriodReceptors, LDLStentsVascular System Injuries