m+Medelevator.RU
← Поиск публикаций
Health and quality of life outcomes · 2014

Validation and comparison of EuroQoL-5 dimension (EQ-5D) and Short Form-6 dimension (SF-6D) among stable angina patients.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wu Jing, Han Yuerong, Zhao Fei-Li, Zhou Jin, Chen Zhijun, Sun He

Аннотация

OBJECTIVES: Several preference-based health-related quality of life (HRQoL) instruments have been published and widely used in different populations. However no consensus has emerged regarding the most appropriate instrument in therapeutic area of stable angina. This study compared and validated the psychometric properties of two generic preference-based instruments, the EQ-5D and SF-6D, among Chinese stable angina patients.

METHODS: Convergent validity of the EQ-5D and SF-6D was examined with eight a priori hypotheses from stable angina patients in conjunction with Seattle Angina Questionnaire (SAQ). Responsiveness was compared using the effect size (ES), relative efficiency (RE) and receiver operating characteristic (ROC) curves. Agreement between the EQ-5D and SF-6D was tested using intra-class correlation coefficient (ICC) and Bland-Altman plot. Factors affecting utility difference were explored with multiple linear regression analysis.

RESULTS: In 411 patients (mean age 68.08 ± 11.35), mean utility scores (SD) were 0.78 (0.15) for the EQ-5D and 0.68 (0.12) for the SF-6D. Validity was demonstrated by the moderate to strong correlation coefficients (Range: 0.368-0.594, P< 0.001) for five of the eight hypotheses in both the EQ-5D and SF-6D. There were no serious floor effects for the EQ-5D and SF-6D, but ceiling effects for the EQ-5D were large. The areas under ROC of them all exceeded 0.5 (0.660-0.814, P< 0.001). The SF-6D showed a better discriminative capacity (ES: 0.573 to 1.179) between groups with different stable-angina-specific health status than the EQ-5D (ES: 0.426 to 1.126). RE suggested that the SF-6D (RE: 44.8 to 177.8%) was more efficient than the EQ-5D except for physical function. Poor agreement between them was observed with ICC (0.448, P< 0.001) and Bland-Altman plot analysis. Multiple liner regression showed that clinical variables significantly (P< 0.05) influenced differences in utility scores between the EQ-5D and SF-6D.

CONCLUSIONS: Both EQ-5D and SF-6D are valid and sensitive preference-based HRQoL instruments in Chinese stable angina patients. The SF-6D may be a more effective tool with lower ceiling effect and greater sensitivity. Further study is needed to compare other properties, such as reliability and longitudinal response.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты