MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ancard.2014.08.011

Медицинская библиотека · Annales de cardiologie et d'angeiologie · 2014

Assessment of coronary bypass graft patency by first-line multi-detector computed tomography.

Pesenti-Rossi D, Baron N, Georges J-L, Augusto S, Gibault-Genty G, Livarek B

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The purpose of the study was to assess whether a strategy based on a MDCT performed routinely before CA can reduce the radiation dose during the CA, without increased global exposure in patients who need imaging of CABG. A total of 147 consecutive patients were included. The radiation dose during CA (KAP 12.1 vs 22.0 Gy/cm(2), P<.01) and the volume of iodinated contrast (155 vs 200 mL, P<.02) were reduced when preceded by a MDCT. Patients' cumulative exposures were not different in the 2 strategies (5.0 vs 5.1 mSv, P=.76). MDCT performed in first line is a valuable strategy for the assessment of CABG.

Для цитирования: Pesenti-Rossi D, Baron N, Georges J-L, Augusto S, Gibault-Genty G, Livarek B. Assessment of coronary bypass graft patency by first-line multi-detector computed tomography.. Annales de cardiologie et d'angeiologie. 2014. DOI: 10.1016/j.ancard.2014.08.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.