in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis.

Dulay Samuel, Rivas Lourdes, Miserere Sandrine, Pla Laura, Berdún Sergio, Parra Johanna, Eixarch Elisenda, Gratacós Eduard, Illa Míriam, Mir Mònica, Samitier Josep

СтатьяПеревод пока не подготовлен

Аннотация

Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4-9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications.

Для цитирования: Dulay Samuel, Rivas Lourdes, Miserere Sandrine, Pla Laura, Berdún Sergio, Parra Johanna, Eixarch Elisenda, Gratacós Eduard, Illa Míriam, Mir Mònica, Samitier Josep. in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis.. Talanta. 2020. DOI: 10.1016/j.talanta.2020.122045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.