MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2021.11.014

Медицинская библиотека · Journal of cardiology · 2021

Albuminuria predicts worsening renal function after transcatheter aortic valve replacement.

Tobe Akihiro, Tanaka Akihito, Tokuda Yoshiyuki, Fujii Taro, Furusawa Kenji, Ishii Hideki, Usui Akihiko, Murohara Toyoaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The impact of albuminuria on worsening renal function (WRF) and clinical outcomes after transcatheter aortic valve replacement (TAVR) is unknown.

METHODS

Overall, 142 patients who underwent TAVR for severe aortic stenosis were divided into two groups based on the preoperative urinary albumin-to-creatinine ratio (ACR): high (ACR ≥30 mg/g) and low (ACR <30 mg/g). The incidence of WRF (an absolute increase in serum creatinine level of ≥0.3 mg/dL or ≥1.5-fold from baseline or dialysis initiation) at 6 months after TAVR and the incidence of all-cause death and heart failure readmission during follow-up were investigated.

RESULTS

Half of the examined patients [n=71/142 (50.0%)] had a high ACR. Patients with a high ACR more frequently had WRF at 6 months than those with a low ACR (17.6% vs. 2.9%, p=0.004). Multivariate analysis showed a high ACR was independently associated with WRF (odds ratio, 7.76; 95% confidence interval, 1.62-37.30; p=0.01), whereas baseline estimated glomerular filtration rate <60 mL/min/1.73m² was not (odds ratio, 0.34; 95% confidence interval, 0.08-1.50; p=0.15). Patients with a high ACR had a higher risk of composite outcomes of all-cause death and heart failure readmission (p=0.002).

CONCLUSIONS

Preoperative albuminuria (ACR ≥30 mg/g) was independently associated with WRF at 6 months after TAVR. Furthermore, patients with an ACR ≥30 mg/g had higher risks of all-cause death and heart failure readmission than those with an ACR <30 mg/g.

Для цитирования: Tobe Akihiro, Tanaka Akihito, Tokuda Yoshiyuki, Fujii Taro, Furusawa Kenji, Ishii Hideki, Usui Akihiko, Murohara Toyoaki. Albuminuria predicts worsening renal function after transcatheter aortic valve replacement.. Journal of cardiology. 2021. DOI: 10.1016/j.jjcc.2021.11.014.