American heart journal · 2022
The efficacy of single-lead implantable cardioverter-defibrillator with atrial sensing dipole to detect atrial fibrillation and to reduce inappropriate therapy according to atrial sensing ON or OFF: Rationale and design of the SMART-CONTROL study, a prospective multicenter randomized trial.
СтатьяПоддержка исследования: вне правительства СШАПротокол клинического исследованияНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gwag Hye Bin, Kim Hye Ree, Park Seung-Jung, Kim Juwon, Chung Tae Wan, Choi Ji-Hoon, Kim Ju Youn, Park Kyoung-Min, On Young Keun, Kim June Soo
Аннотация
BACKGROUND: Few studies have compared the efficacy of single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (VDD-ICD) and conventional single-chamber ICD from the aspect of atrial fibrillation (AF) detection or inappropriate ICD therapy reduction. In the SMART-CONTROL trial (NCT03932604), we primarily aim to investigate whether the atrial sensing capability of VDD-ICD is useful in AF detection and inappropriate therapy reduction by randomly activating or deactivating the atrial sensing function.
METHODS AND DESIGN: This study was designed as a prospective, multicenter, open-label, randomized trial to enroll 640 patients with no history of clinical AF or rhythm control for AF within 1 year who were undergoing the implantation of VDD-ICD system. Patients are assigned randomly to atrial sensing "ON" or "OFF" group, with crossover allowed during follow-up. The coprimary outcomes are the incidence of AF detection and inappropriate ICD therapy over a 2-year follow-up period. The secondary outcomes include non-AF atrial tachyarrhythmia, ventricular tachyarrhythmia with or without ICD therapy, thromboembolic events, bleeding, heart failure hospitalization, mortality, a composite of adverse cardiovascular events, and long-term atrial sensing stability or variability.
CONCLUSION: We expect that this trial can evaluate the efficacy of a single-lead ICD system on various clinical outcomes including AF detection and inappropriate therapy reduction, and ultimately provide guidance to selection of ICD system.
METHODS AND DESIGN: This study was designed as a prospective, multicenter, open-label, randomized trial to enroll 640 patients with no history of clinical AF or rhythm control for AF within 1 year who were undergoing the implantation of VDD-ICD system. Patients are assigned randomly to atrial sensing "ON" or "OFF" group, with crossover allowed during follow-up. The coprimary outcomes are the incidence of AF detection and inappropriate ICD therapy over a 2-year follow-up period. The secondary outcomes include non-AF atrial tachyarrhythmia, ventricular tachyarrhythmia with or without ICD therapy, thromboembolic events, bleeding, heart failure hospitalization, mortality, a composite of adverse cardiovascular events, and long-term atrial sensing stability or variability.