m+Medelevator.RU
← Поиск публикаций
Journal of electrocardiology · 2022

Contribution of the vectorcardiogram in the differential diagnosis of Brugada electrocardiographic pattern.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Madaloso Bruna A, Samesima Nelson, Tobias Nancy M M O, Tavares Caio A M, Pereira Filho Horacio G, Facin Mirella E, Pastore C A

Аннотация

BACKGROUND: The electrocardiogram (ECG) is a powerful tool for differential diagnosis among a group of pathologies with different therapeutic approaches/prognoses, the so-called J-wave syndrome. The vectorcardiogram (VCG) can be used as a complementary method to the ECG in several dubious electrocardiographic alterations.

OBJECTIVE: We carried out a VCG analysis after conceiving and measuring a novel parameter (JT-distance) that allows diagnosis of the Brugada ECG pattern.

METHODS: A retrospective cohort study selected ninety-six ECGs with J-point elevation in V1/V2, ECG superior leads and VCGs, all performed on the same day. A new VCG measurement by Frank method (JT-distance) was conceived and designed in transverse and right sagittal planes by 3 lines drawn 1) at the final third of the QRS loop, comprehending the J-point; 2) at the initial portion of the T loop; 3) a parallel of the J-point line at the beginning of the T loop. JT measure was determined by the distance between parallels. A validation cohort was established in a new sample of thirty-five patients.

RESULTS: JT-distance ≥1.5 mm (tranverse plane) and JT-distance >1.25 mm, in the sagittal plane, differentiated Brugada type-1 from Brugada type-2, early repolarization and others, with 95% sensitivity and 68% specificity. JT-distance <1.5 mm (transverse plane) and JT >1.25 mm (sagittal plane) had 100% sensitivity and 85% specificity for Brugada type-1 diagnosis. A validation cohort showed very similar Cohen's kappa levels (0.65 and 0.77, test and validation cohorts, respectively), with overlapping 95% confidence intervals.

CONCLUSIONS: The novel vectorcardiogram measurement (JT-distance) presented a new diagnostic criterion to identify Brugada pattern. Nevertheless, prospective studies should be performed by other centers to confirm these findings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты