BACKGROUND

Prevalence of atrial fibrillation (AF) is increasing in adult patients with congenital heart disease (CHD). Experience using the cryoballoon to achieve pulmonary vein isolation (PVI) in adult CHD patients is limited. The aim of the present study was to assess the value of PVI by cryoballoon in adult CHD patients and to evaluate the significance of additional radiofrequency (RF) ablation of atrial tachycardia (AT).

PATIENTS AND

METHODS

Prospective data analysis; all patients with CHD and AF and PVI using the cryoballoon from January 2017 through November 2021 were included.

RESULTS

Nineteen patients with various types of CHD were included. Median age was 58 (IQR 47-63) years. A total of 12/19 (63%) patients had had RF ablation of right atrial AT before. Median procedure duration was 225 (IQR 196-261) min. Median fluoroscopy time was 12.3 (IQR 5.2-19.5) min and median freeze time was 32 (IQR 28-36.3) min. Procedural success was achieved in all patients. Additional RF catheter ablation of intraatrial reentrant tachycardia within the left atrium was performed in 3/19 (16%) subjects and within the right atrium in 6/19 (32%) patients. Median follow-up was 26 (IQR 9-49) months. Excluding a 90-day blanking period, recurrence of AF was observed in 6/19 subjects (32%). After one redo procedure deploying RF energy only, 84% of all patients remained free from recurrence. Phrenic nerve palsy was observed in 1 subject.

CONCLUSION

Results after PVI using the cryoballoon plus additional RF ablation of AT were promising (84% success including one redo procedure). Success of AF ablation was unsatisfactory in all patients who had no additional AT ablation. Ablation of any AT in these patients should therefore be considered in addition to PVI.

Для цитирования: Krause Ulrich, Müller Matthias J, Schneider Heike E, Paul Thomas. Catheter ablation of atrial fibrillation using 2nd-generation cryoballoon in congenital heart disease patients - significance of RF ablation of additional atrial macro-reentrant tachycardia.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2022. DOI: 10.1007/s10840-022-01213-0.