MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circulationaha.105.557678

Медицинская библиотека · Circulation · 2006

Projected valve area at normal flow rate improves the assessment of stenosis severity in patients with low-flow, low-gradient aortic stenosis: the multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) study.

Blais Claudia, Burwash Ian G, Mundigler Gerald, Dumesnil Jean G, Loho Nicole, Rader Florian, Baumgartner Helmut, Beanlands Rob S, Chayer Boris, Kadem Lyes, Garcia Damien, Durand Louis-Gilles, Pibarot Philippe

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

We sought to investigate the use of a new parameter, the projected effective orifice area (EOAproj) at normal transvalvular flow rate (250 mL/s), to better differentiate between truly severe (TS) and pseudo-severe (PS) aortic stenosis (AS) during dobutamine stress echocardiography (DSE). Changes in various parameters of stenosis severity have been used to differentiate between TS and PS AS during DSE. However, the magnitude of these changes lacks standardization because they are dependent on the variable magnitude of the transvalvular flow change occurring during DSE.

METHODS AND

RESULTS

The use of EOAproj to differentiate TS from PS AS was investigated in an in vitro model and in 23 patients with low-flow AS (indexed EOA <0.6 cm2/m2, left ventricular ejection fraction < or =40%) undergoing DSE and subsequent aortic valve replacement. For an individual valve, EOA was plotted against transvalvular flow (Q) at each dobutamine stage, and valve compliance (VC) was derived as the slope of the regression line fitted to the EOA versus Q plot; EOAproj was calculated as EOAproj=EOArest+VCx(250-Q(rest)), where EOArest and Q(rest) are the EOA and Q at rest. Classification between TS and PS was based on either response to flow increase (in vitro) or visual inspection at surgery (in vivo). EOAproj was the most accurate parameter in differentiating between TS and PS both in vitro and in vivo. In vivo, 15 of 23 patients (65%) had TS and 8 of 23 (35%) had PS. The percentage of correct classification was 83% for EOAproj and 91% for indexed EOAproj compared with percentages of 61% to 74% for the other echocardiographic parameters usually used for this purpose.

CONCLUSIONS

EOAproj provides a standardized evaluation of AS severity with DSE and improves the diagnostic accuracy for distinguishing TS and PS AS in patients with low-flow, low-gradient AS.

Для цитирования: Blais Claudia, Burwash Ian G, Mundigler Gerald, Dumesnil Jean G, Loho Nicole, Rader Florian, Baumgartner Helmut, Beanlands Rob S, Chayer Boris, Kadem Lyes, Garcia Damien, Durand Louis-Gilles, Pibarot Philippe. Projected valve area at normal flow rate improves the assessment of stenosis severity in patients with low-flow, low-gradient aortic stenosis: the multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) study.. Circulation. 2006. DOI: 10.1161/circulationaha.105.557678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление