MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0066-782x2004001600003

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2004

Cryopreserved aortic homograft for aortic valve replacement: immediate results.

Gerola Luís Roberto, Araújo Wesley, Kin Hyong C, Silva Gabriela E F, Pereira Filho Armindo, Vargas Guilherme Flora, Buffolo Enio

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess immediate clinical and echocardiographic results of the use of cryopreserved aortic homografts for aortic valve replacement.

METHODS

Eighteen patients with aortic valve disease underwent aortic valve replacement, receiving a cryopreserved aortic homograft, 15 were male, 10 had aortic regurgitation, and 8 had aortic stenosis. Age ranged from 18 to 65 years (mean, 44.5 +/- 18.14 years). Four patients had infective endocarditis, 12 patients were in functional class II, and 6 patients were in functional class III (NYHA). Left ventricular function was normal in 15 patients.

RESULTS

Hospital mortality was 5.5% (1 patient) due to respiratory distress; the other patients were discharged from the hospital between the fifth and eighth postoperative days in functional class I. Maximal aortic transvalvular gradient, on echocardiography, ranged from 0 to 30 mmHg, with a mean of 10.9 +/- 9.2 mmHg. Five patients did not have any degree of regurgitation through the aortic homograft, 11 patients (61.1%) had minimal regurgitation, and 2 had mild regurgitation. Duration of extracorporeal circulation ranged from 130 to 220 minutes (mean, 183.9 +/- 36.7 minutes). Duration of aortic clamping ranged from 102 to 168 minutes (mean, 139.14 +/- 25.10 minutes). Bleeding in the postoperative period ranged from 210 to 1220 mL, with a mean of 511.4 +/- 335.1 mL. Reoperations were not necessary. Duration of orotracheal intubation ranged from 2 hours 50 minutes to 17 hours with a mean of 9.14 +/- 3.6 hours.

CONCLUSION

Cryopreserved aortic homografts may be routinely used with low hospital morbidity and mortality.

Для цитирования: Gerola Luís Roberto, Araújo Wesley, Kin Hyong C, Silva Gabriela E F, Pereira Filho Armindo, Vargas Guilherme Flora, Buffolo Enio. Cryopreserved aortic homograft for aortic valve replacement: immediate results.. Arquivos brasileiros de cardiologia. 2004. DOI: 10.1590/s0066-782x2004001600003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.