Cusp extension technique for bicuspid aortic valve in Turner-like stigmata.

Oshima Yoshihiro, Koto Keiju, Shimazu Chikashi, Misaki Takuro, Ichida Fukiko, Hashimoto Ikuo

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

A 19-year-old girl with bicuspid aortic valve and Turner-like stigmata underwent a successful repair with a cusp extension technique using fresh autologous pericardium for aortic insufficiency. She also had a simultaneous artificial graft replacement for ascending aortic dilatation. Aortic valve function showed no significant stenosis and slight insufficiency 2 years postoperatively. This technique is recommended to avoid a Ross or Ross/Konno procedure because of its ready availability, simplicity and excellent midterm results.

Для цитирования: Oshima Yoshihiro, Koto Keiju, Shimazu Chikashi, Misaki Takuro, Ichida Fukiko, Hashimoto Ikuo. Cusp extension technique for bicuspid aortic valve in Turner-like stigmata.. Asian cardiovascular & thoracic annals. 2004. DOI: 10.1177/021849230401200320.