MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jdent.2024.105485

Медицинская библиотека · Journal of dentistry · 2024

Assessment of clinical reproducibility for intraoral scanning on different anatomical regions for the complete maxillary edentulous arch with two intraoral scanners.

Cameron Andrew B, Abuzar Menaka A, Tadakamadla Santosh Kumar, Evans Jane L

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

There are no in vivo studies comparing multiple intraoral scanners (IOSs) for the completely edentulous maxilla to polyvinyl siloxane (PVS) impressions. Investigations comparing IOSs to PVS impressions focus on comparing the overall scan and not individual anatomical regions. This study aims to evaluate two IOSs and compare the results for different anatomical regions on the completely edentulous maxillary arch.

MATERIALS AND

METHODS

Nineteen patients were recruited with a completely edentulous maxilla. A custom tray was constructed, and a sectional border moulded PVS impression was made then scanned. An intraoral scan of the edentulous maxilla with a Trios 4 (3Shape, B/V) and Medit i700 (Medit corporation) was then captured. The scans were analysed for negative and positive surface deviations along with root mean square for distinct anatomical regions compared to the polyvinyl siloxane impression. A two-way ANOVA followed by Tukey HSD post hoc tests for each scanner was conducted for all anatomical regions to determine differences between the regions.

RESULTS

There was no significant difference between the two IOSs included in this study for all anatomical regions or for the overall scan (0.435, 0.38), palatal vault (0.18, 0.181), ridge (0.218, 0.209), and post dam (0.233, 0.229) anatomical regions. Significantly higher deviation (p < 0.05) was observed for the peripheral regions (0.607, 0.557) for each intraoral scanners Trio 4 and Medit i700.

CONCLUSION

Different IOSs can capture all areas of a completely edentulous maxilla consistently, when compared to a PVS impression, apart from the peripheries.

CLINICAL SIGNIFICANCE: Care should be taken when scanning the peripheries. These regions are problematic to capture with an IOS. Border moulding should still be considered the optimal impression technique for the completely edentulous maxilla. The IOSs investigated did not make a difference for the anatomical regions investigated.

Для цитирования: Cameron Andrew B, Abuzar Menaka A, Tadakamadla Santosh Kumar, Evans Jane L. Assessment of clinical reproducibility for intraoral scanning on different anatomical regions for the complete maxillary edentulous arch with two intraoral scanners.. Journal of dentistry. 2024. DOI: 10.1016/j.jdent.2024.105485.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.