MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.214.2.r00fe04393

Медицинская библиотека · Radiology · 2000

Parathyroid glands: combination of (99m)Tc MIBI scintigraphy and US for demonstration of parathyroid glands and nodules.

De Feo M L, Colagrande S, Biagini C, Tonarelli A, Bisi G, Vaggelli L, Borrelli D, Cicchi P, Tonelli F, Amorosi A, Serio M, Brandi M L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the appropriate choice of imaging techniques for localization of nodular lesions of parathyroid glands.

MATERIALS AND

METHODS

First, computed tomographic (CT), magnetic resonance (MR), ultrasonographic (US), and technetium 99m methoxyisobutyl-isonitrile (MIBI) scintigraphic images in 49 patients with primary hyperparathyroidism were retrospectively evaluated. A single-blind, prospective study that included 16 patients with primary hyperparathyroidism was then conducted. MR, US, scintigraphic, and color Doppler US images of the neck were obtained and analyzed.

RESULTS

In the retrospective study, CT, MR imaging, and US had low sensitivity (13%, 17%, and 27%, respectively) and specificity (39%, 65%, and 65%, respectively). Scintigraphy had 57% sensitivity and 85% specificity. In the prospective study, the use of latest-generation MR and US equipment and the participation of experienced operators led to improved sensitivity and specificity for these techniques. The combination of US and scintigraphy resulted in improved sensitivity (96%), specificity (83%), and positive and negative predictive values (88% and 94%, respectively), relative to the results obtained with either method alone. Doppler US was of little help in the setting of small glands.

CONCLUSIONS

The combination of (99m)Tc MIBI scintigraphy and US performed by well-trained operators with up-to-date instruments appeared to be the best diagnostic tool for the preoperative diagnosis of parathyroid disease.

Для цитирования: De Feo M L, Colagrande S, Biagini C, Tonarelli A, Bisi G, Vaggelli L, Borrelli D, Cicchi P, Tonelli F, Amorosi A, Serio M, Brandi M L. Parathyroid glands: combination of (99m)Tc MIBI scintigraphy and US for demonstration of parathyroid glands and nodules.. Radiology. 2000. DOI: 10.1148/radiology.214.2.r00fe04393.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.