MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1309/ajcpwe2hbfcgdids

Медицинская библиотека · American journal of clinical pathology · 2015

Flow cytometric identification of immunophenotypically aberrant T-cell clusters on skin shave biopsy specimens from patients with mycosis fungoides.

Horna Pedro, Kurant Danielle, Sokol Lubomir, Sotomayor Eduardo M, Moscinski Lynn, Glass L Frank

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess the ability of flow cytometry (FC) to detect putative neoplastic T-cell subsets on skin shave biopsy (SSB) specimens from patients with mycosis fungoides (MF) and to study the immunophenotype of skin-infiltrating tumor cells in MF.

METHODS

SSB specimens from patients with suspected MF were bisected and submitted for both FC and routine histopathology. Six-dimensional gating strategies were applied to identify putative neoplastic cells, independently from their expected immunophenotype.

RESULTS

Aberrant T cells were detected by FC in 18 of 33 SBB specimens, of which all had clinicomorphologic features of MF. Of the remaining 15 SSB specimens, six had clinicomorphologic features of MF and nine were diagnosed with benign inflammatory dermatoses. Unexpectedly, CD26 was aberrantly overexpressed in 11 (73%) and lost in three (20%) of 15 SSB specimens from patients with MF where this antigen was evaluated. Other detected aberrancies included CD3 dim- (13/18 [72%]), CD7 dim- (15/18 [83%]), and CD4-/CD8- (3/18 [17%]).

CONCLUSIONS

FC is capable of identifying putative neoplastic cells on SSB specimens from patients with MF. Bright homogeneous CD26 expression is a common and previously undescribed immunophenotypic aberrancy on MF skin infiltrates.

Для цитирования: Horna Pedro, Kurant Danielle, Sokol Lubomir, Sotomayor Eduardo M, Moscinski Lynn, Glass L Frank. Flow cytometric identification of immunophenotypically aberrant T-cell clusters on skin shave biopsy specimens from patients with mycosis fungoides.. American journal of clinical pathology. 2015. DOI: 10.1309/ajcpwe2hbfcgdids.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.