MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13246-024-01408-x

Медицинская библиотека · Physical and engineering sciences in medicine · 2024

Semi-supervised learning towards automated segmentation of PET images with limited annotations: application to lymphoma patients.

Yousefirizi Fereshteh, Shiri Isaac, O Joo Hyun, Bloise Ingrid, Martineau Patrick, Wilson Don, Bénard François, Sehn Laurie H, Savage Kerry J, Zaidi Habib, Uribe Carlos F, Rahmim Arman

СтатьяПеревод пока не подготовлен

Аннотация

Manual segmentation poses a time-consuming challenge for disease quantification, therapy evaluation, treatment planning, and outcome prediction. Convolutional neural networks (CNNs) hold promise in accurately identifying tumor locations and boundaries in PET scans. However, a major hurdle is the extensive amount of supervised and annotated data necessary for training. To overcome this limitation, this study explores semi-supervised approaches utilizing unlabeled data, specifically focusing on PET images of diffuse large B-cell lymphoma (DLBCL) and primary mediastinal large B-cell lymphoma (PMBCL) obtained from two centers. We considered 2-[18F]FDG PET images of 292 patients PMBCL (n = 104) and DLBCL (n = 188) (n = 232 for training and validation, and n = 60 for external testing). We harnessed classical wisdom embedded in traditional segmentation methods, such as the fuzzy clustering loss function (FCM), to tailor the training strategy for a 3D U-Net model, incorporating both supervised and unsupervised learning approaches. Various supervision levels were explored, including fully supervised methods with labeled FCM and unified focal/Dice loss, unsupervised methods with robust FCM (RFCM) and Mumford-Shah (MS) loss, and semi-supervised methods combining FCM with supervised Dice loss (MS + Dice) or labeled FCM (RFCM + FCM). The unified loss function yielded higher Dice scores (0.73 ± 0.11; 95% CI 0.67-0.8) than Dice loss (p value < 0.01). Among the semi-supervised approaches, RFCM + αFCM (α = 0.3) showed the best performance, with Dice score of 0.68 ± 0.10 (95% CI 0.45-0.77), outperforming MS + αDice for any supervision level (any α) (p < 0.01). Another semi-supervised approach with MS + αDice (α = 0.2) achieved Dice score of 0.59 ± 0.09 (95% CI 0.44-0.76) surpassing other supervision levels (p < 0.01). Given the time-consuming nature of manual delineations and the inconsistencies they may introduce, semi-supervised approaches hold promise for automating medical imaging segmentation workflows.

Для цитирования: Yousefirizi Fereshteh, Shiri Isaac, O Joo Hyun, Bloise Ingrid, Martineau Patrick, Wilson Don, Bénard François, Sehn Laurie H, Savage Kerry J, Zaidi Habib, Uribe Carlos F, Rahmim Arman. Semi-supervised learning towards automated segmentation of PET images with limited annotations: application to lymphoma patients.. Physical and engineering sciences in medicine. 2024. DOI: 10.1007/s13246-024-01408-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.