MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Minerva cardioangiologica · 2015

Effectiveness of a novel biodegradable polymer, sirolimus-eluting stent platform in percutaneous coronary intervention.

Dominici Marcello, Arrivi Alessio, Bazzucchi Marco, De Paolis Marcella, Milici Caterina, Bock Carlo, Placanica Attilio, Lazzari Ludovico, Diletti Roberto, Boschetti Enrico

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this registry is to report the immediate and long-term safety and efficacy of the Biotronik Orsiro stent in an unselected population during everyday practice.

METHODS

Between May 2012 and June 2013, 246 consecutive coronary angioplasty procedures were performed using at least one Orsiro drug-eluting stent, in 225 patients and 303 lesions.

RESULTS

Diabetes was present in 34.7% of patients. Procedures were non-elective percutaneous coronary intervention (PCI) in 17.1% of cases and acute coronary syndromes were 55.1%. Radial vascular access was used in 78% of cases, multivessel PCI was performed in 19.5% of the procedures. In 81.6% of cases lesions were B2/C type, 20.7% of procedures had bifurcation lesions. Procedural success was 99.6%. No acute thrombosis occurred. Clinical follow-up median period was 24.3 (±8.28) months and FU was available in 93.7% of patients. Death for any cause occurred in 11 patients (5.2%), 6 of them were non cardiac-related. Cardiac-related death rate was 2.4%. Two patients had in-stent restenosis. The overall target lesion failure rate was 3.3%.

CONCLUSIONS

This observational data regards our experience with Biotronik Orsiro stent in an unselected population. This initial data, although limited by a mainly clinical follow-up and restricted number of patients, confirms the good clinical performance of this sirolimus-eluting stent with a biodegradable polymer in everyday practice, including complex lesions, according to current larger studies in the literature.

Для цитирования: Dominici Marcello, Arrivi Alessio, Bazzucchi Marco, De Paolis Marcella, Milici Caterina, Bock Carlo, Placanica Attilio, Lazzari Ludovico, Diletti Roberto, Boschetti Enrico. Effectiveness of a novel biodegradable polymer, sirolimus-eluting stent platform in percutaneous coronary intervention.. Minerva cardioangiologica. 2015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.