m+Medelevator.RU
← Поиск публикаций
Drug design, development and therapy · 2024

Up-and-Down Determination of Different Crystalloid Coload Volumes on the ED 90 of Prophylactic Norepinephrine Infusion for Preventing Postspinal Anesthesia Hypotension During Cesarean Section.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Yi, Xiong Xiangsheng, Qin Rui, Guo Lei, Shi Yongqiang, Ni Xinli

Аннотация

BACKGROUND: Fluid loading improves hemodynamic stability and reduces the incidence rate of post-spinal anesthesia hypotension when prophylactic vasopressors are administered. We investigated the impact of different crystalloid coload volumes on the 90% effective dose (ED) of prophylactic norepinephrine infusion for preventing post-spinal anesthesia hypotension in non-hypertensive patients undergoing cesarean section.

METHODS: Patients were randomly allocated to receive one of the different crystalloid coload volumes (0mL/kg [0mL/kg Group], 5mL kg [5mL/kg Group], and 10mL kg [10mL/kg Group]) in combination with prophylactic norepinephrine infusion immediately after the induction of spinal anesthesia. The prophylactic norepinephrine infusion doses were determined using the up-and-down sequential allocation methodology, with an initial dose of 0.025 μg/kg/min and a gradient of 0.005 μg/kg/min. The primary endpoint was the effective dose at which 90% (ED 90) of patients responded to prophylactic norepinephrine infusion for preventing post-spinal anesthesia hypotension.

RESULTS: The estimated effective dose of norepinephrine infusion, at which 90% (ED 90) of patients responded, was found to be 0.084 (95% CI, 0.070 to 0.86), 0.074 (95% CI, 0.059 to 0.077), and 0.063 (95% CI, 0.053 to 0.064) μg/kg/min in the three groups, respectively.

CONCLUSION: A crystalloid coload of 5 mL/kg or 10 mL/kg, as opposed to the groups receiving 0 mL/kg crystalloid coloads, resulted in a reduction of approximately 11.9% and 25.0%, respectively, in the ED90 of prophylactic norepinephrine infusion for preventing post-spinal anesthesia hypotension during cesarean section.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты