Diabetes Screening: Detection and Application of Saliva 1,5-Anhydroglucitol by Liquid Chromatography-Mass Spectrometry.

Jian Chaohui, Zhao Aihua, Ma Xiaojing, Ge Kun, Lu Wei, Zhu Wei, Wang Yufei, Zhou Jian, Jia Wei, Bao Yuqian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

CONTEXT: Unlike other commonly used invasive blood glucose-monitoring methods, saliva detection prevents patients from suffering physical uneasiness. However, there are few studies on saliva 1,5-anhydroglucitol (1,5-AG) in patients with diabetes mellitus (DM).

OBJECTIVE

This study aimed to evaluate the effectiveness of saliva 1,5-AG in diabetes screening in a Chinese population.

DESIGN AND

PARTICIPANTS

This was a population-based cross-sectional study. A total of 641 subjects without a valid diabetic history were recruited from September 2018 to June 2019. Saliva 1,5-AG was measured with liquid chromatography-mass spectrometry.

MAIN OUTCOME MEASURES: DM was defined per American Diabetes Association criteria. The efficiency of saliva 1,5-AG for diabetes screening was analyzed by receiver operating characteristic curves, and the optimal cutoff point was determined according to the Youden index.

RESULTS

Saliva 1,5-AG levels in subjects with DM were lower than those in subjects who did not have DM (both P < .05). Saliva 1,5-AG was positively correlated with serum 1,5-AG and negatively correlated with blood glucose and glycated hemoglobin (HbA1c) (all P < .05). The optimal cutoff points of saliva 1,5-AG0 and 1,5-AG120 for diabetes screening were 0.436 μg/mL (sensitivity: 63.58%, specificity: 60.61%) and 0.438 μg/mL (sensitivity: 62.25%, specificity: 60.41%), respectively. Fasting plasma glucose (FPG) combined with fasting saliva 1,5-AG reduced the proportion of people who required an oral glucose tolerance test by 47.22% compared with FPG alone.

CONCLUSION

Saliva 1,5-AG combined with FPG or HbA1c improved the efficiency of diabetes screening. Saliva 1,5-AG is robust in nonfasting measurements and a noninvasive and convenient tool for diabetes screening.

Для цитирования: Jian Chaohui, Zhao Aihua, Ma Xiaojing, Ge Kun, Lu Wei, Zhu Wei, Wang Yufei, Zhou Jian, Jia Wei, Bao Yuqian. Diabetes Screening: Detection and Application of Saliva 1,5-Anhydroglucitol by Liquid Chromatography-Mass Spectrometry.. The Journal of clinical endocrinology and metabolism. 2020. DOI: 10.1210/clinem/dgaa114.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.