MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joen.2016.09.008

Медицинская библиотека · Journal of endodontics · 2016

External Cervical Resorption: A Comparison of the Diagnostic Efficacy Using 2 Different Cone-beam Computed Tomographic Units and Periapical Radiographs.

Vaz de Souza Daniel, Schirru Elia, Mannocci Francesco, Foschi Federico, Patel Shanon

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The aim of this study was to compare the diagnostic efficacy of 2 cone-beam computed tomographic (CBCT) units with parallax periapical (PA) radiographs for the detection and classification of simulated external cervical resorption (ECR) lesions.

METHODS

Simulated ECR lesions were created on 13 mandibular teeth from 3 human dry mandibles. PA and CBCT scans were taken using 2 different units, Kodak CS9300 (Carestream Health Inc, Rochester, NY) and Morita 3D Accuitomo 80 (J Morita, Kyoto, Japan), before and after the creation of the ECR lesions. The lesions were then classified according to Heithersay's classification and their position on the root surface. Sensitivity, specificity, positive predictive values, negative predictive values, and receiver operator characteristic curves as well as the reproducibility of each technique were determined for diagnostic accuracy.

RESULTS

The area under the receiver operating characteristic value for diagnostic accuracy for PA radiography and Kodak and Morita CBCT scanners was 0.872, 0.99, and 0.994, respectively. The sensitivity and specificity for both CBCT scanners were significantly better than PA radiography (P < .001). There was no statistical difference between the sensitivity and specificity of the 2 scanners. The percentage of correct diagnoses according to the tooth type was 87.4% for the Kodak scanner, 88.3% for the Morita scanner, and 48.5% for PA radiography.The ECR lesions were correctly identified according to the tooth surface in 87.8% Kodak, 89.1% Morita and 49.4% PA cases. The ECR lesions were correctly classified according to Heithersay classification in 70.5% of Kodak, 69.2% of Morita, and 39.7% of PA cases.

CONCLUSIONS

This study revealed that both CBCT scanners tested were equally accurate in diagnosing ECR and significantly better than PA radiography. CBCT scans were more likely to correctly categorize ECR according to the Heithersay classification compared with parallax PA radiographs.

Для цитирования: Vaz de Souza Daniel, Schirru Elia, Mannocci Francesco, Foschi Federico, Patel Shanon. External Cervical Resorption: A Comparison of the Diagnostic Efficacy Using 2 Different Cone-beam Computed Tomographic Units and Periapical Radiographs.. Journal of endodontics. 2016. DOI: 10.1016/j.joen.2016.09.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.