JTCVS open · 2022
Ratio of the false lumen to the true lumen is associated with long-term prognosis after surgical repair of acute type A aortic dissection.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Igarashi Takashi, Sato Yoichi, Satokawa Hirono, Takase Shinya, Iwai-Takano Masumi, Seto Yuki, Yokoyama Hitoshi
Аннотация
OBJECTIVES: The aim of this study was to assess potential predictors of aortic events after an emergency surgery for acute type A aortic dissection, especially paying attention to the findings of computed tomography (CT) performed immediately after the surgery.
METHODS: Between January 2001 and December 2015, 72 patients, who were diagnosed as having Stanford type A acute aortic dissection with a patent false lumen in the descending thoracic aorta, survived the emergency operation, and had postoperative CT scan data, were included in this study (mean follow-up, 8.2 ± 3.8 years; range 0.8-17.4 years). From the CT scan data, the diameter of the false lumen (FL-D) and true lumen (TL-D) were measured, and the FL-D:TL-D ratio was calculated. Long-term outcomes of the FL-D > TL-D group (n = 30) and the FL-D < TL-D group (n = 42) were compared.
RESULTS: In the late follow-up, 17 aortic events in the downstream aorta were observed. The FL-D:TL-D ratio (P = .01) was an adjusted risk of aortic events in multivariable analysis. The rates of freedom from aortic events at 5 and 9 years were superior in the FL-D < TL-D group than in the FL-D > TL-D group (92.0% and 88.6% vs 81% and 60.7%; log rank P < .05).
CONCLUSIONS: Our results suggest that the false lumen:true lumen ratio predicts long-term prognosis after surgical repair of acute type A aortic dissection.
METHODS: Between January 2001 and December 2015, 72 patients, who were diagnosed as having Stanford type A acute aortic dissection with a patent false lumen in the descending thoracic aorta, survived the emergency operation, and had postoperative CT scan data, were included in this study (mean follow-up, 8.2 ± 3.8 years; range 0.8-17.4 years). From the CT scan data, the diameter of the false lumen (FL-D) and true lumen (TL-D) were measured, and the FL-D:TL-D ratio was calculated. Long-term outcomes of the FL-D > TL-D group (n = 30) and the FL-D < TL-D group (n = 42) were compared.
RESULTS: In the late follow-up, 17 aortic events in the downstream aorta were observed. The FL-D:TL-D ratio (P = .01) was an adjusted risk of aortic events in multivariable analysis. The rates of freedom from aortic events at 5 and 9 years were superior in the FL-D < TL-D group than in the FL-D > TL-D group (92.0% and 88.6% vs 81% and 60.7%; log rank P < .05).