m+Medelevator.RU
← Поиск публикаций
Medical oncology (Northwood, London, England) · 2017

Microwave ablation of liver malignancies: comparison of effects and early outcomes of percutaneous and intraoperative approaches with different liver conditions : New advances in interventional oncology: state of the art.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

De Cobelli Francesco, Marra Paolo, Ratti Francesca, Ambrosi Alessandro, Colombo Michele, Damascelli Anna, Sallemi Claudio, Gusmini Simone, Salvioni Marco, Diana Pietro, Cipriani Federica, Venturini Massimo, Aldrighetti Luca, Del Maschio Alessandro

Аннотация

Liver thermal ablation is an alternative treatment for hepatocellular carcinoma (HCC) and secondary liver malignancies. Microwave ablation (MWA) produces large ablation zones (AZ) in short time; however, AZ prediction is based on preclinical ex vivo models, rising concerns about reproducibility and safety in humans. We aimed to investigate the effects produced by a new-generation MWA system on human liver in vivo with different approaches (percutaneous or intraoperative) and liver conditions (cirrhosis or previous chemotherapy treatment), in comparison with manufacturer-provided predictions based on ex vivo animal models. Complete tumor ablation (CA) and early clinical outcomes were also assessed. From October 2014, 60 consecutive patients (cirrhotic = 31; non-cirrhotic = 10; chemotherapy-treated = 19) with 81 liver nodules (HCC = 31; mets = 50) underwent MWA procedures (percutaneous = 30; laparotomic = 18; laparoscopic = 12), with a 2450 MHz/100 W generator with Thermosphere™ Technology (Emprint™, Medtronic). A contrast-enhanced CT or MR was performed after one month to assess CA and measure AZ. A linear correlation between AZ volumes and ablation times was observed in vivo, without differences from manufacturer-provided ex vivo predictions in all operative approaches and liver conditions. Other independent variables (sex, age, nodule location) showed no relationship when added to the model. Median (IQR) longitudinal and transverse roundness-indexes of the AZs were, respectively, 0.77(0.13) and 0.93(0.11). CA at 1 month was 93% for percutaneous and 100% for intraoperative procedures (p = 0.175). Thirty-day morbidity and mortality were 3% and 0%. MWA with Thermosphere™ Technology produces predictable AZs on human liver in vivo, according to manufacturer-provided ex vivo predictions. In our experience, this new-generation MWA system is effective and safe to treat liver malignancies in different operative and clinical settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты