Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2015

Aortic root volume is associated with contained rupture of the aortic annulus in balloon-expandable transcatheter aortic valve replacement.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Reinöhl Jochen, Psyrakis Dimitrios, Kaier Klaus, Kodirov Sodikdjon, Siepe Matthias, Gutmann Anja, von zur Mühlen Constantin, Moser Martin, Ahrens Ingo, Pache Gregor, Zirlik Andreas, Langer Mathias, Beyersdorf Friedhelm, Zehender Manfred, Bode Christoph, Blanke Philipp

Аннотация

BACKGROUND: Aortic annulus rupture is a rare, but potentially fatal complication of transcatheter aortic valve replacement (TAVR), especially when it occurs by balloon-expandable devices. In order to improve the predictability of procedures and avoid ruptures we investigated whether or not the aortic root volume measures is a useful indicator of risk, and if it could be useful for the prosthesis size selection.

METHODS AND RESULTS: From a retrospective series of 172 TAVR patients, seven experienced contained aortic annulus ruptures. The receiver operating curves were used to illustrate sensitivity and specificity of the different aortic annulus size and aortic root volume measures. The annulus area oversizing of ≥20% resulted in a sensitivity of 100%, specificity of 55.76%, and positive predictive value (PPV) of 8.75%. In patients receiving 26 mm prostheses, the aortic root volume (ARV <13600 mm(3)) provided a better specificity and PPV (79.63 and 18.52%, respectively). A two-step testing procedure considering the area derived average annulus diameter (Darea <23 mm) as a first separating parameter and then the ARV (<13,600 mm(3)) as a further indicator showed the most promising results with the PPV of 31.25%. Regardless of the procedure steps no false negative results were predicted.

CONCLUSIONS: Our data show that the ARV provides a better predictive value for correct prosthesis sizing than established annulus measurements, especially in 'borderline' annuli. We suggest a two-step testing procedure for prostheses size selection, considering Darea and ARV to minimize the risk of annulus rupture. Prospective studies and examination of larger datasets are warranted to confirm these findings.