MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12659/msm.893956

Медицинская библиотека · Medical science monitor : international medical journal of experimental and clinical research · 2015

Effects of Noninvasive Positive-Pressure Ventilation with Different Interfaces in Patients with Hypoxemia after Surgery for Stanford Type A Aortic Dissection.

Yang Yi, Sun Lizhong, Liu Nan, Hou Xiaotong, Wang Hong, Jia Ming

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Hypoxemia is a severe perioperative complication that can substantially increase intensive care unit and hospital stay and mortality. The aim of this study was to determine the effects of non-invasive positive-pressure ventilation (NIPPV) in patients with hypoxemia after surgery for Stanford type A aortic dissection, and to compare the effects of helmet and mask NIPPV.

MATERIAL AND

METHODS

We recruited 40 patients who developed hypoxemia within 24 h after extubation after surgery for Stanford type A aortic dissection in the Beijing Anzhen Hospital. The patients were randomly divided into the helmet and mask NIPPV groups. The primary endpoints were blood oxygenation levels at 1 and 6 h after initiation and at the end of the treatment. The secondary endpoint was patient outcome, including mortality; incidence of pulmonary atelectasis, pneumonia, re-intubation, and sepsis; and length of ICU and hospital stays.

RESULTS

NIPPV improved oxygenation in both groups. Compared with pretreatment levels, the oxygenation index (PaO2/FiO2), PaO2, PaCO2, and respiratory rate (RR) improved in the initial (0-1 h), maintenance (1-6 h), and end stages of the treatment (P<0.05). Compared with mask ventilation, helmet ventilation better improved pH, PaO2, SpO2, PaO2/FiO2, and decreased PaCO2 in the 3 stages (P<0.05). The incidence of major complications, including flatulence, intolerance, and facial pressure sores, was significantly lower with helmet ventilation.

CONCLUSIONS

NIPPV effectively improved oxygenation and reduced PaCO2 in patients who developed hypoxemia soon after extubation following surgery for Stanford type A aortic dissection. Compared with mask NIPPV, helmet NIPPV more rapidly increased PaO2 and reduced PaCO2, increased patient tolerance and comfort, and reduced complications.

Для цитирования: Yang Yi, Sun Lizhong, Liu Nan, Hou Xiaotong, Wang Hong, Jia Ming. Effects of Noninvasive Positive-Pressure Ventilation with Different Interfaces in Patients with Hypoxemia after Surgery for Stanford Type A Aortic Dissection.. Medical science monitor : international medical journal of experimental and clinical research. 2015. DOI: 10.12659/msm.893956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.