Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2015

Delivery balloon-induced ascending aortic dissection: An unusual complication during transcatheter aortic valve implantation.

Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yashima Fumiaki, Hayashida Kentaro, Fukuda Keiichi

Аннотация

Transcatheter aortic valve implantation (TAVI) is a relatively mature technique that is generally accepted as a promising treatment for inoperable patients and those who are high-risk candidates for surgical aortic replacement. Although severe complications in the aortic valve complex, such as annular or aortic root rupture, are not frequently observed, these events could easily lead to catastrophic outcomes, and therefore remain major issues during TAVI. However, there remains a paucity of data describing these catastrophic complications because of their low incidence. We encountered the case of an 88-year-old woman complicated by a dissection of the ascending aorta during TAVI from an "unusual" cause: injury due to the delivery of a balloon-expandable valve to a very narrow and heavily calcified sinotubular junction (STJ). This is the first report to demonstrate the mechanism of this complication; even a delivery balloon, not a stent frame, with low inflation pressure might injure a narrow STJ and lead to an aortic dissection. Therefore, the use of oversized delivery balloons should be avoided in patients with a narrow and calcified STJ. © 2015 Wiley Periodicals, Inc.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты