m+Medelevator.RU
← Поиск публикаций
PloS one · 2022

Safety of paclitaxel-coated devices in the femoropopliteal arteries: A systematic review and meta-analysis.

СтатьяМетаанализСистематический обзорПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Chenyang, Yin Guosheng

Аннотация

BACKGROUND: Clinical benefit of paclitaxel-coated devices for patients with peripheral arterial disease has been confirmed in randomized controlled trials (RCTs). A meta-analysis published in 2018 identified late mortality risk over a long follow-up period due to use of paclitaxel-coated devices in the femoropopliteal arteries, which caused enormous controversy and debates globally. This study aims to further evaluate the safety of paclitaxel-coated devices by incorporating the most recently published data.

METHODS: We searched for candidate studies in PubMed (MEDLINE), Scopus, EMBASE (Ovid) online databases, government web archives and international cardiovascular conferences. Safety endpoints of interest included all-cause mortality rates at one, two and five years and the risk ratio (RR) was used as the summary measure. The primary analysis was performed using random-effects models to account for potential clinical heterogeneity.

FINDINGS: Thirty-nine RCTs including 9164 patients were identified. At one year, the random-effects model yielded a pooled RR of 1.06 (95% CI [0.87, 1.29]) indicating no difference in short-term all-cause deaths between the paclitaxel and control groups (crude mortality, 4.3%, 214/5025 versus 4.5%, 177/3965). Two-year mortality was reported in 26 RCTs with 382 deaths out of 3788 patients (10.1%) in the paclitaxel arm and 299 out of 2955 patients (10.1%) in the control arm and no association was found between increased risk of death and usage of paclitaxel-coated devices (RR 1.08, 95% CI [0.93, 1.25]). Eight RCTs recorded all-cause deaths up to five years and a pooled RR of 1.18 (95% CI [0.92, 1.51]) demonstrated no late mortality risk due to use of paclitaxel-coated devices (crude mortality, paclitaxel 18.2%, 247/1360 versus control 15.2%, 122/805).

CONCLUSIONS: We found no significant difference in either short- or long-term all-cause mortalities between patients receiving paclitaxel-coated and uncoated devices. Further research on the longer-term safety of paclitaxel usage (e.g., 8- or 10-year) is warranted.

REGISTRATION: PROSPERO, CRD42021246291.