MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00167-021-06805-3

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021

Direct suturing quadriceps tendon to a continuous loop with a suspensory button provides biomechanically superior fixation in ACL reconstruction.

Kamada Kohei, Nagai Kanto, Nagamune Kouki, Hoshino Yuichi, Nakanishi Yuta, Araki Daisuke, Kanzaki Noriyuki, Matsushita Takehiko, Kuroda Ryosuke

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the biomechanical strength of different fixation configurations using suspensory buttons in a soft-tissue quadriceps tendon (QT) grafts in anterior cruciate ligament (ACL) reconstruction.

METHODS

Forty bovine QTs, 6-cm long and 10-mm wide, were allocated into four groups with different suture configurations using suspensory buttons (n = 10 in each group): Group A, a baseball suture with a knot tied to the continuous loop with a suspensory button; Group B, same configuration as in Group A but with the knot tied at the opposite end of the baseball suture; Group C, a continuous loop with a suspensory button stitched directly to the QT with simple sutures, and Group D, a baseball suture tied directly to a suspensory button. Biomechanical testing was performed by preloading followed by cyclic loading for 500 cycles between 10 and 100 N. The length of elongation (mm) and maximum load to failure (N) were recorded, and compared among the four groups.

RESULTS

Group C showed significantly smaller elongation (4.1 mm [95% CI 3.1-5.2]) than Group A (8.2 mm [95% CI 7.0-9.4]), Group B (10.5 mm [95% CI 7.7-13.3]), and Group D (8.5 mm [95% CI 7.0-9.9]) (A-C; P = 0.004, B-C; P = 0.0001, C-D; P = 0.0018). The maximum load to failure in Group C (386 N [95%CI 306-466]) was significantly higher than that in Group A (196 N [95% CI 141-251]), Group B (226 N [95% CI 164-289]), and Group D (212 N [95%CI 171-253]) (A-C; P = 0.0001, B-C; P = 0.0009, C-D; P = 0.0002). No significant differences were observed between Group A, B, and D in terms of elongation and maximum load to failure.

CONCLUSION

The soft-tissue QT graft fixation configuration stitched directly to a continuous loop with suspensory button using simple sutures exhibits small elongation and high maximum load to failure among the four configurations. Regarding clinical relevance, direct suturing of the soft-tissue QT to a continuous loop with a suspensory button may be advantageous for femoral fixation in ACL reconstruction from a biomechanical perspective, and warrant future development of a novel fixation device using this principle.

Другие публикации по теме

Anterior Cruciate LigamentAnterior Cruciate Ligament ReconstructionBiomechanical PhenomenaCattle
Для цитирования: Kamada Kohei, Nagai Kanto, Nagamune Kouki, Hoshino Yuichi, Nakanishi Yuta, Araki Daisuke, Kanzaki Noriyuki, Matsushita Takehiko, Kuroda Ryosuke. Direct suturing quadriceps tendon to a continuous loop with a suspensory button provides biomechanically superior fixation in ACL reconstruction.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2021. DOI: 10.1007/s00167-021-06805-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.