MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/003655201750305477

Медицинская библиотека · Scandinavian journal of gastroenterology · 2001

Endomysial and tissue transglutaminase antibodies in coeliac sera: a comparison not influenced by previous serological testing.

Biagi F, Pezzimenti D, Campanella J, Vadacca G B, Corazza G R

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Since transglutaminase was shown to be the antigen of endomysial antibodies (EMA), it has become possible to screen for coeliac disease (CD) with an enzyme-linked immunosorbent assay (ELISA) for transglutaminase antibodies (TTA). However, it is possible that sera used to show that TTA are found in CD were obtained from patients diagnosed because they were positive for EMA. So, a comparison between EMA and TTA has not been possible so far.

METHODS

EMA and TTA were tested in sera from 52 controls and 56 untreated CD patients, who had not undergone serological testing. Samples were tested for TTA with an ELISA kit. Based on the ROC analysis of a pilot study, results were considered as either positive, borderline, or negative. EMA were analysed by indirect immunofluorescence on monkey oesophagus.

RESULTS

Forty-nine CD patients were positive for TTA, six borderline, one negative. Forty-four controls were negative, seven borderline, one positive. If we consider borderline results to be positive, sensitivity is 98.2% and specificity 84.6%. EMA were positive in 53 CD patients; the controls were all negative. Performing TTA in all cases and EMA only in the few TTA borderline cases (12.0%) would have a sensitivity of 94.6% and a specificity of 98.1%.

CONCLUSIONS

This study is the first to compare TTA with EMA. Due to 100% specificity and high sensitivity, EMA seems to be the most accurate coeliac antibody. Conversely, TTA offer advantages in terms of sensitivity and simplicity. A satisfactory strategy is to use TTA first and then EMA to confirm the borderline results.

Для цитирования: Biagi F, Pezzimenti D, Campanella J, Vadacca G B, Corazza G R. Endomysial and tissue transglutaminase antibodies in coeliac sera: a comparison not influenced by previous serological testing.. Scandinavian journal of gastroenterology. 2001. DOI: 10.1080/003655201750305477.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.