DOI 10.1007/s00330-005-2797-7

Медицинская библиотека · European radiology · 2005

Peripheral artery stent visualization and in-stent stenosis analysis in 16-row computed tomography: an in-vitro evaluation.

Herzog Christopher, Grebe Christine, Mahnken Andreas, Balzer Joern O, Mack Martin G, Zangos Stefan, Ackermann Hanns, Schaller Stefan, Seifert Tobias, Ohnesorge Bernd, Vogl Thomas J

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The accuracy of 16-row multidetector CT in the visualization of different peripheral artery stents and in the appraisal of in-stent stenosis was assessed. Nine different stent types (nitinol and stainless steel) with three diameters (6, 8 and 10 mm) were used; altogether 27 stents were analyzed in a barrel-shaped vascular model. Low-grade (<40%) and high-grade (>60%) in-stent stenoses were simulated by polyurethane sticks (70 HU) of differing diameters (2-6 mm). Imaging was performed with 16x0.75-mm detector collimation, 130 mAs, 120 kV, 12-mm table feed/rotation, 1.0-mm slice thickness and 0.5-mm increment. The stent diameter, strut thickness, in-stent attenuation values, degree and degree of in-stent stenosis were evaluated. Nitinol stents showed significantly (P<10-6) less stent lumen narrowing, artificial strut thickening and overestimation of the degree of in-stent stenoses than stainless steel stents. In-stent attenuation values and artificial strut thickening were significantly (P<10-6) lower in 10- and 8-mm stents than in 6-mm stents. Stent lumen narrowing was significantly less in 10-mm stents than in 8-mm (P<10-4) or 6-mm (P<10-6) stents. In-stent stenoses were significantly overestimated, irrespective of the stent diameter. In 6-mm stents overestimation was significantly higher than in 8-mm (P<0.01) or 10-mm stents (P<10-6). Under in-vitro conditions 16-row MDCT allowed an accurate identification of in-stent stenosis, but significantly overestimated the effective degree of the stenosis.

Для цитирования: Herzog Christopher, Grebe Christine, Mahnken Andreas, Balzer Joern O, Mack Martin G, Zangos Stefan, Ackermann Hanns, Schaller Stefan, Seifert Tobias, Ohnesorge Bernd, Vogl Thomas J. Peripheral artery stent visualization and in-stent stenosis analysis in 16-row computed tomography: an in-vitro evaluation.. European radiology. 2005. DOI: 10.1007/s00330-005-2797-7.

Предметные рубрики MeSH