DOI 10.1080/003655200750024362
Reliance on serum endomysial antibody testing underestimates the true prevalence of coeliac disease by one fifth.
Аннотация
BACKGROUND
Although IgA endomysial antibody (EmA) is currently the serologic test of choice in selecting suspected coeliac patients for duodenal biopsies, false-negative cases have been reported and may be more common than previous studies suggest. We assessed the sensitivity of EmA for patients with biopsy-confirmed villous atrophy (VA).
METHODS
We studied 89 patients without IgA deficiency for whom biopsy had not been primarily prompted by a positive EmA result. VA was graded as partial, subtotal, or total (PVA, STVA, TVA). Serum EmA was assayed with indirect immunofluorescence.
RESULTS
The sensitivity of EmA for VA was 78% (69 of 89) and was similar for PVA (79%) and ST/TVA (77%). Only 4 of the 20 EmA-negative patients had increased serum IgA-class antigliadin antibody levels as measured with enzyme-linked immunosorbent assay. All seronegative patients who complied with dietary gluten exclusion responded clinically, with histologic improvement after 12 months in 8 (67%) of 12 patients who had follow-up biopsies.
CONCLUSIONS
EmA-negative coeliac disease is common. Reliance on EmA testing to select patients for biopsy will result in significant underdiagnosis.