MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mri.2004.08.021

Медицинская библиотека · Magnetic resonance imaging · 2004

An MRA study of vascular stenosis in a pig model using CH3-DTPA-Gd (NMS60) and Gd-DTPA.

D'Arceuil Helen E, de Crespigny Alexander J, Pelc Lorie, Howard Diane, Alley Mark, Seri Shigemi, Hashiguchi Yuji, Nakatani Akira, Moseley Michael E

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: This study used an experimental arterial stenosis model in pigs to evaluate the utility of a new medium-weight MRI contrast agent, NMS60 (a synthetic oligomeric Gd complex containing three Gd(3+) atoms, molecular weight of 2158 Da) compared to Gd-DTPA for contrast-enhanced MRA.

MATERIALS AND

METHODS

We used six male white hybrid pigs. Under anesthesia, one femoral artery was exposed and an inflatable cuff placed around it. The cuff was tightened around the vessel until 80-90% stenosis was achieved using digital subtraction angiography as a guide. Animals were then immediately transferred to the MRI scanner and images acquired pre- and postcontrast injection (0.1 or 0.2 mmol Gd/kg Gd-DTPA or NMS60, as a rapid bolus) using high-resolution and dynamic MRA.

RESULTS

The dynamic MRA scans acquired during contrast bolus injection clearly showed the stenosed femoral artery as a segment of close to zero enhancement during the arterial phase of the bolus transit, while on the high-resolution scans the stenosis was difficult to detect due to venous signal contamination. The signal-to-noise at peak enhancement on the dynamic scans was significantly greater with 0.1 mmol Gd/kg NMS60 compared to 0.1 mmol Gd/kg Gd-DTPA (14.6 vs. 9.9, P < .05) and not significantly greater than 0.2 mmol Gd/kg (14.6 vs. 12.8).

DISCUSSION AND

CONCLUSION

This new medium-weight contrast agent demonstrated significantly greater enhancement than Gd-DTPA and may be valuable to aid detection of vascular stenosis in humans.

Для цитирования: D'Arceuil Helen E, de Crespigny Alexander J, Pelc Lorie, Howard Diane, Alley Mark, Seri Shigemi, Hashiguchi Yuji, Nakatani Akira, Moseley Michael E. An MRA study of vascular stenosis in a pig model using CH3-DTPA-Gd (NMS60) and Gd-DTPA.. Magnetic resonance imaging. 2004. DOI: 10.1016/j.mri.2004.08.021.