MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/ae97d3

Медицинская библиотека · Physics in medicine and biology · 2026

An optically coupled hybrid semi-monolithic PET detector for simplified DOI and position decoding.

Zhao Yangyang, Yang Hang, Huang Wenjie, Zhang Xiaoqin, Jiang Xiaolong, Niu Ming, Zeng Xiangtao, He Wen, Wei Qingyang, Gu Zheng

СтатьяПеревод пока не подготовлен

Аннотация

Objective.Positron emission tomography (PET) detectors that encode depth-of-interaction (DOI) while achieving high timing and energy resolution are essential for long axial field-of-view (FOV) clinical PET systems. In this work, we propose an optically coupled hybrid semi-monolithic detector design, in which a pixelated scintillator array is coupled to a monolithic scintillator slab using optical adhesive. This design enables DOI capability while simplifying positioning calibration and preserving high timing and energy performance.Approach.Based on this concept, a prototype detector composed of a single-layer hybrid structure was fabricated and comprehensively evaluated. The prototype consists of aarray of pixelated lutetium-yttrium oxyorthosilicate (LYSO) crystals, each measuringwith a pitch of 3.2 mm, coupling via a high-refractive-index adhesive () to a monolithic LYSO slab of. The interface surfaces between the pixelated array and the monolithic slab were unpolished. The detector was read out using a TOFPET2 application-specific integrated circuit (ASIC).Main results.Experimental results show clearly separated pseudo-pixel event clusters in the flood image, enabling planar event positioning using a conventional energy-weighted average method. Using a 400-600 keV energy window, the detector achieved an average DOI resolution ofmm, an average energy resolution of, an intrinsic spatial resolution of 1.7 mm along the layer-stacking direction andmm along the pixelated array direction, and a coincidence timing resolution of 281 ps.Significance.These results demonstrate that the proposed optically coupled hybrid semi-monolithic detector balances detector performance (including DOI, timing and energy resolution) with calibration complexity. The design offers a promising detector solution for long axial FOV clinical PET systems.

Для цитирования: Zhao Yangyang, Yang Hang, Huang Wenjie, Zhang Xiaoqin, Jiang Xiaolong, Niu Ming, Zeng Xiangtao, He Wen, Wei Qingyang, Gu Zheng. An optically coupled hybrid semi-monolithic PET detector for simplified DOI and position decoding.. Physics in medicine and biology. 2026. DOI: 10.1088/1361-6560/ae97d3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.