MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.26455

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2016

Impact of total stent length after cobalt chromium everolimus-eluting stent implantation on 3-year clinical outcomes.

Hiromasa Takashi, Kuramitsu Shoichi, Shinozaki Tomohiro, Jinnouchi Hiroyuki, Morinaga Takashi, Kobayashi Yohei, Domei Takenori, Soga Yoshimitsu, Shirai Shinichi, Ando Kenji

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The objective was to assess whether total stent length (TSL) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation was associated with long-term clinical outcomes.

BACKGROUND

The impact of TSL after CoCr-EES implantation on long-term clinical outcomes remained unclear.

METHODS

A total of 1,007 consecutive patients with 1,382 lesions treated only with CoCr-EES were analyzed. Patients and lesions were divided into tertile group: TSL per patient (TSL-P) (PA [8-23 mm], n = 382; PB [23-46 mm], n = 312; and PC [46-204 mm], n = 313), and TSL per lesion (TSL-L) (LA [8-18 mm], n = 486; LB [18-28 mm], n = 475; and LC [28-140 mm], n = 421). The cumulative 3-year incidence of clinically driven target-lesion revascularization (CD-TLR) and definite stent thrombosis (ST) based on TSL-P and TSL-L groupings were accessed.

RESULTS

After inverse probability of weighted adjustment, the cumulative 3-year incidence of CD-TLR for the TSL-P and TSL-L were higher in the PC and LC groups than in the other groups (hazard ratio [HR] 2.92, 95% confidence intervals [CI] 1.66-5.15, P < 0.001 vs. PA; HR 2.49, 95% CI 1.47-4.20, P < 0.001 vs. PB; HR 1.94, 95% CI 1.15-3.28, P = 0.01 vs. LA; HR 2.80, 95% CI 1.73-4.54, P < 0.001 vs. LB, respectively). No significant differences in the cumulative 3-year incidence of definite ST were observed in both TSL-P and TSL-L groups.

CONCLUSIONS

TSL after CoCr-EES implantation has significantly impact on CD-TLR rate through 3 years, but it is not associated with an increased incidence of definite ST. © 2016 Wiley Periodicals, Inc.

Для цитирования: Hiromasa Takashi, Kuramitsu Shoichi, Shinozaki Tomohiro, Jinnouchi Hiroyuki, Morinaga Takashi, Kobayashi Yohei, Domei Takenori, Soga Yoshimitsu, Shirai Shinichi, Ando Kenji. Impact of total stent length after cobalt chromium everolimus-eluting stent implantation on 3-year clinical outcomes.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.26455.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.