Hoppmann P, Kufner S, Cassese S, Wiebe J, Schneider S, Pinieck S, Scheler L, Bernlochner I, Joner M, Schunkert H, Laugwitz K-L, Kastrati A, Byrne R A
Аннотация
OBJECTIVES: We aimed to analyze angiographic and clinical results of patients undergoing BRS implantation in a real-world setting.
BACKGROUND: Angiographic and clinical outcome data from patients undergoing implantation of drug-eluting bioresorbable stents (BRS) in routine clinical practice is scant.
METHODS: Consecutive patients undergoing implantation of everolimus-eluting BRS at two high-volume centers in Munich, Germany were enrolled. Data were collected prospectively. All patients were scheduled for angiographic surveillance 6-8 months after stent implantation. Quantitative coronary angiographic analysis was performed in a core laboratory. Clinical follow-up was performed to 12 months and events were adjudicated by independent assessors.
RESULTS: A total of 419 patients were studied. Mean age was 66.6 ± 10.9 years, 31.5% had diabetes mellitus, 76.1% had multivessel disease, and 39.0% presented with acute coronary syndrome; 49.0% of lesions were AHA/ACC type B2/C, 13.1% had treatment of bifurcation lesions. Mean reference vessel diameter was 2.89 ± 0.46 mm. At angiographic follow-up in-stent late loss was 0.26 ± 0.51 mm, in-segment diameter stenosis was 27.5 ± 16.1, and binary angiographic restenosis was 7.5%. At 12 months, the rate of death, myocardial infarction, or target lesion revascularization was 13.1%. Definite stent thrombosis occurred in 2.6%.
CONCLUSIONS: The use of everolimus-eluting BRS in routine clinical practice is associated with high antirestenotic efficacy in patients undergoing angiographic surveillance. Overall clinical outcomes at 12 months are satisfactory though stent thrombosis rates are not insignificant. Further study with longer term follow-up and larger numbers of treated patients is required before we can be sure of the role of these devices in clinical practice.
BACKGROUND: Angiographic and clinical outcome data from patients undergoing implantation of drug-eluting bioresorbable stents (BRS) in routine clinical practice is scant.
METHODS: Consecutive patients undergoing implantation of everolimus-eluting BRS at two high-volume centers in Munich, Germany were enrolled. Data were collected prospectively. All patients were scheduled for angiographic surveillance 6-8 months after stent implantation. Quantitative coronary angiographic analysis was performed in a core laboratory. Clinical follow-up was performed to 12 months and events were adjudicated by independent assessors.
RESULTS: A total of 419 patients were studied. Mean age was 66.6 ± 10.9 years, 31.5% had diabetes mellitus, 76.1% had multivessel disease, and 39.0% presented with acute coronary syndrome; 49.0% of lesions were AHA/ACC type B2/C, 13.1% had treatment of bifurcation lesions. Mean reference vessel diameter was 2.89 ± 0.46 mm. At angiographic follow-up in-stent late loss was 0.26 ± 0.51 mm, in-segment diameter stenosis was 27.5 ± 16.1, and binary angiographic restenosis was 7.5%. At 12 months, the rate of death, myocardial infarction, or target lesion revascularization was 13.1%. Definite stent thrombosis occurred in 2.6%.
CONCLUSIONS: The use of everolimus-eluting BRS in routine clinical practice is associated with high antirestenotic efficacy in patients undergoing angiographic surveillance. Overall clinical outcomes at 12 months are satisfactory though stent thrombosis rates are not insignificant. Further study with longer term follow-up and larger numbers of treated patients is required before we can be sure of the role of these devices in clinical practice.
Предметные рубрики MeSH
Absorbable ImplantsAcute Coronary SyndromeAgedCardiovascular AgentsCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisCoronary ThrombosisCoronary VesselsDrug-Eluting StentsEverolimusFemaleGermanyHospitals, High-VolumeHumansMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPredictive Value of TestsProsthesis DesignRegistriesRisk FactorsTime FactorsTreatment Outcome