MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mca.0000000000000315

Медицинская библиотека · Coronary artery disease · 2016

Extreme late-phase observation using coronary angioscopy until 7 years after sirolimus-eluting stent implantation.

Shimura Tetsuro, Yamamoto Masanori, Takano Masamichi, Okamatsu Kentaro, Inami Shigenobu, Murakami Daisuke, Munakata Ryo, Inami Toru, Kurihara Osamu, Kano Seiji, Seino Yoshihiko, Shimizu Wataru, Mizuno Kyoichi

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Little is known about the very late-phase morphological vessel characteristics within the sirolimus-eluting stent (SES).

METHODS AND

RESULTS

We assessed a total of 12 patients with 15 SES implantations who underwent repeat angiographic and angioscopic procedures after 5 and 7 years. The degree of neointimal stent coverage (NSC) was classified as follows: grade 0, uncovered struts; grade 1, visible struts through a thin neointima; or grade 2, invisible struts with complete neointimal coverage. The maximum and minimum NSC grades were evaluated and the existence of in-stent thrombus was also recorded for all patients. The prevalence of a maximum NSC grade of 2 increased and that of a minimum NSC grade of 0 decreased, although there was no significant difference in prevalence between 5 and 7 years. One of four in-stent thrombus identified at 5 years had disappeared from 5 to 7 years and a new thrombus was found in another patient at 7 years. Thus, the incidence of in-stent thrombus did not change from 5 to 7 years. In one case, a thrombus was observed inside the angiographic aneurysmal change, but none of the thrombi were related to adverse events.

CONCLUSION

This angioscopic study reported gradual arterial repair and continuous delayed healing associated with subclinical thrombus formation 7 years after SES deployment.

Для цитирования: Shimura Tetsuro, Yamamoto Masanori, Takano Masamichi, Okamatsu Kentaro, Inami Shigenobu, Murakami Daisuke, Munakata Ryo, Inami Toru, Kurihara Osamu, Kano Seiji, Seino Yoshihiko, Shimizu Wataru, Mizuno Kyoichi. Extreme late-phase observation using coronary angioscopy until 7 years after sirolimus-eluting stent implantation.. Coronary artery disease. 2016. DOI: 10.1097/mca.0000000000000315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.