BACKGROUND

Embolic protection devices (EPDs) have been designed and introduced to reduce distal embolization and peri-procedural myocardial infarction during saphenous vein graft (SVG) intervention. Current guidelines give a class I recommendation to EPD use during SVG intervention when technically feasible. However, the routine use of these devices has recently been debated.

METHODS

We analyzed 1,359 patients undergoing isolated SVG intervention between 2008 and 2013 in the British Columbia Cardiac Registry. We analyzed (a) post-procedural TIMI flow; and (b) target vessel revascularization (TVR) and mortality at 1 and 2 years.

RESULTS

EPD use was an independent predictor of post-procedural TIMI 2/3 flow (OR = 2.38, 95% CI: 1.51-3.74, P < 0.001). At 1 year, EPD use was an independent predictor for lower TVR (HR = 0.35, 95% CI: 0.14-0.85, P = 0.021) and a trend towards lower mortality (HR = 0.45, 95% CI: 0.18-1.10, P = 0.082). These associations were lost at 2 years where EPD use was not predictive of mortality (HR = 0.62, 95% CI: 0.33-1.17, P = 0.144) or TVR (HR = 0.70, 95% CI: 0.41-1.17, P = 0.176). These findings were confirmed in propensity-matched and inverse probability treatment weighted analyses.

CONCLUSIONS

In this analysis of patients undergoing SVG intervention, EPD use was a strong predictor for improved post-procedural TIMI flow. Whilst EPD use was associated with lower TVR and a trend for lower mortality at 1 year, these associations were lost at 2 years. These findings would appear to support the use of EPD for SVG intervention. © 2015 Wiley Periodicals, Inc.

Для цитирования: Iqbal M Bilal, Nadra Imad J, Ding Lillian, Fung Anthony, Aymong Eve, Chan Albert W, Hodge Steven, Della Siega Anthony, Robinson Simon D, British Columbia Cardiac Registry Investigators. Embolic protection device use and its association with procedural safety and long-term outcomes following saphenous vein graft intervention: An analysis from the British Columbia Cardiac registry.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2015. DOI: 10.1002/ccd.26237.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.