DOI 10.1007/s00595-025-03106-x
Endotoxin in drainage fluid as an early and predictive marker of anastomotic leakage after colorectal surgery.
Аннотация
PURPOSE: To assess the predictive value of the endotoxin (ET) assay for the detection of anastomotic leakage (AL) after colorectal surgery (CRS).
METHODS
ET levels in the drainage fluid were measured using endotoxin scattering photometry (ET-ESP) and turbidimetric (ET-TUB) assays on postoperative day (POD) zero, POD1 and POD3, comparing tumor necrosis factor (TNF)-α.
RESULTS
AL was observed in 8 (4.9%) of the 162 patients. ET-ESP, ET-TUB, and TNF-α levels on POD0 and serum C-reactive protein (CRP) on POD1 were significantly elevated in the AL group. The area under the receiver operating characteristic curve (AUROC) for ET-ESP level (0.903) on POD0 showed early and better predictive performance for AL compared to that for ET-TUB (0.869, p = 0.230) and TNF-α (0.758, p = 0.034) levels on POD0; the AUROC for CRP level (0.711) on POD1 was inferior to other parameters. In subgroup analysis, five (3.7%) of 136 patients with colorectal cancer (CRC) developed AL. Additionally, the ET-ESP level on POD0 showed relatively good predictive performance for AL after CRC (AUROC: ET-ESP [0.871], ET-TUB [0.840], and TNF-α [0.737] on POD0).
CONCLUSION
ET levels in drainage fluid, especially those measured using ESP, on POD0 may have an early predictive ability to detect AL post-CRS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.