MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3346/jkms.2022.37.e81

Медицинская библиотека · Journal of Korean medical science · 2022

A Retrospective Clinical Evaluation of an Artificial Intelligence Screening Method for Early Detection of STEMI in the Emergency Department.

Kim Dongsung, Hwang Ji Eun, Cho Youngjin, Cho Hyoung-Won, Lee Wonjae, Lee Ji Hyun, Oh Il-Young, Baek Sumin, Lee Eunkyoung, Kim Joonghee

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Rapid revascularization is the key to better patient outcomes in ST-elevation myocardial infarction (STEMI). Direct activation of cardiac catheterization laboratory (CCL) using artificial intelligence (AI) interpretation of initial electrocardiography (ECG) might help reduce door-to-balloon (D2B) time. To prove that this approach is feasible and beneficial, we assessed the non-inferiority of such a process over conventional evaluation and estimated its clinical benefits, including a reduction in D2B time, medical cost, and 1-year mortality.

METHODS

This is a single-center retrospective study of emergency department (ED) patients suspected of having STEMI from January 2021 to June 2021. Quantitative ECG (QCG™), a comprehensive cardiovascular evaluation system, was used for screening. The non-inferiority of the AI-driven CCL activation over joint clinical evaluation by emergency physicians and cardiologists was tested using a 5% non-inferiority margin.

RESULTS

Eighty patients (STEMI, 54 patients [67.5%]) were analyzed. The area under the curve of QCG score was 0.947. Binned at 50 (binary QCG), the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 98.1% (95% confidence interval [CI], 94.6%, 100.0%), 76.9% (95% CI, 60.7%, 93.1%), 89.8% (95% CI, 82.1%, 97.5%) and 95.2% (95% CI, 86.1%, 100.0%), respectively. The difference in sensitivity and specificity between binary QCG and the joint clinical decision was 3.7% (95% CI, -3.5%, 10.9%) and 19.2% (95% CI, -4.7%, 43.1%), respectively, confirming the non-inferiority. The estimated median reduction in D2B time, evaluation cost, and the relative risk of 1-year mortality were 11.0 minutes (interquartile range [IQR], 7.3-20.0 minutes), 26,902.2 KRW (22.78 USD) per STEMI patient, and 12.39% (IQR, 7.51-22.54%), respectively.

CONCLUSION

AI-assisted CCL activation using initial ECG is feasible. If such a policy is implemented, it would be reasonable to expect some reduction in D2B time, medical cost, and 1-year mortality.

Для цитирования: Kim Dongsung, Hwang Ji Eun, Cho Youngjin, Cho Hyoung-Won, Lee Wonjae, Lee Ji Hyun, Oh Il-Young, Baek Sumin, Lee Eunkyoung, Kim Joonghee. A Retrospective Clinical Evaluation of an Artificial Intelligence Screening Method for Early Detection of STEMI in the Emergency Department.. Journal of Korean medical science. 2022. DOI: 10.3346/jkms.2022.37.e81.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.