m+Medelevator.RU
← Поиск публикаций
BMC cardiovascular disorders · 2022

Preoperative evaluation of pulmonary hypertension in lung transplant candidates: echocardiography versus right heart catheterization.

Сравнительное исследованиеСтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Abu Tal, Levi Amos, Hasdai David, Kramer Mordechai R, Bental Tamir, Bdolah-Abram Tali, Shiyovich Arthur, Samara Abed, Vaknin-Assa Hana, Perl Leor, Rosengarten Dror, Shapira Yaron, Kornowski Ran, Skalsky Keren

Аннотация

BACKGROUND: Right heart catheterization (RHC) and echocardiography are both routinely used for pulmonary artery systolic pressure (PASP) assessment in lung transplantation (LT) candidates, although this is not mandated by current guidelines. We aimed to explore the performance of echocardiographic PASP as an indicator of pulmonary hypertension in LT candidates, in order to assess the necessity of RHC.

METHODS: From a retrospective registry of 393 LT candidates undergoing RHC and echocardiography during 2015-2019, patients were assessed for the presence of pulmonary hypertension (PH), defined as mean pulmonary artery pressure (mPAP) above 20 mmHg, according to two methods-echocardiography and RHC. The primary outcome was the correlation between the PASP estimated by echocardiography to that measured by RHC. Secondary outcomes were the prediction value of the echocardiographic evaluation and its accuracy.

RESULTS: The mean value of PASP estimated by echocardiography was 49.5 ± 20.0 mmHg, compared to 42.5 ± 18.0 mmHg measured by RHC. The correlation between the two measurements was moderate (Pearson's correlation: r = 0.609, p < 0.01). Echocardiography PASP measurements were moderately discriminative to diagnose PH, with an area under the curve (AUC) of 0.72 (95% CI 0.66-0.77). Echocardiographic overestimation of PASP of more than 10 mmHg was found in 35.0% of the patients, and underestimation was found in 11.6% of the patients.

CONCLUSION: In the pre-surgical evaluation of LT candidates, echocardiographic estimation of PASP had moderate correlation and limited accuracy compared to the PASP measured by RHC. We thus recommend performing routine RHC to all LT candidates, regardless of the echocardiographic estimation of PASP.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты