DOI 10.1016/j.echo.2022.02.003
Echocardiographic Biventricular Coupling Index to Predict Precapillary Pulmonary Hypertension.
Аннотация
BACKGROUND
Pulmonary hypertension (PH) is a frequent and detrimental condition. Right heart catheterization (RHC) is the gold standard to identify PH subtype (precapillary from postcapillary PH) and is key for treatment allocation. In this study, the novel echocardiographic biventricular coupling index (BCI), based on the ratio between right ventricular stroke work index and left ventricular E/E' ratio, was tested for the discrimination of PH subtype using RHC as the comparator.
METHODS
BCI was derived in 334 consecutive patients who underwent transthoracic echocardiography and RHC for all indications. BCI was then tested in a validation cohort of 1,349 patients.
RESULTS
The accuracy of BCI to identify precapillary PH was high in the derivation cohort (area under the curve, 0.82; 95% CI, 0.78-0.88; P < .001; optimal cut point, 1.9). BCI identified patients with precapillary PH with high accuracy also in the validation cohort (area under the curve, 0.87 [95% CI, 0.85-0.89; P < .001]; subgroup with PH: area under the curve, 0.91 [95% CI, 0.89-0.93; P < .001]; cut point, 1.9; sensitivity, 82%; specificity, 89%; positive predictive value, 77%; negative predictive value, 92%). BCI outperformed both the D'Alto score (Z = 3.56; difference between areas = 0.05; 95% CI, 0.02-0.07; P < .001) and the echocardiographic pulmonary-to-left atrial ratio index (Z = 2.88; difference between areas = 0.02; 95% CI, 0.01-0.04; P = .004).
CONCLUSIONS
BCI is a novel, noninvasive index based on routinely available echocardiographic parameters that identifies with high accuracy patients with precapillary PH. BCI may be of value in the screening workup of patients with PH.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.