Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2024
DIBH reduces right coronary artery and lung radiation dose in right breast cancer loco-regional radiotherapy.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gough Ebony, Ashworth Simon, Moodie Trevor, Wang Wei, Byth Karen, Beldham-Collins Rachael, Buck Jacqueline, Ghattas Samer, Burke Lucinda, Stuart Kirsty E
Аннотация
To determine whether deep inspiratory breath-hold (DIBH) reduces dose to organs-at-risk (OAR), in particular the right coronary artery (RCA), in women with breast cancer requiring right-sided post-mastectomy radiotherapy (PMRT) including internal mammary chain (+IMC) radiotherapy (RT). Fourteen consecutive women requiring right-sided PMRT + IMC were retrospectively identified. Nodal delineation was in accordance with European Society for Radiology and Oncology (ESTRO) guidelines and tangential chest wall fields marked. Patients were planned with Anisotropic Analytical Algorithm using free-breathing (FB) and DIBH datasets. Dose was calculated using Acuros External Beam algorithm. FB and DIBH dose comparisons were analyzed for heart, RCA and right lung, as were chest wall and IMC planning target volumes (PTVs). DIBH vs FB resulted in median decreases of: the RCA mean dose by 0.6Gray (Gy) (interquartile range (IQR) 0.1, 1.9) (p = 0.002), RCA max dose by 1.8Gy (IQR 0.8, 6.1) (p = 0.002), and V5Gy by 2.9% (IQR 0.0, 37.2) (p = 0.016). RCA data indicated no statistically significant dosimetric reduction ≥10Gy. A median reduction of 1.7Gy (c -0.0, 7.1) (p = 0.019) in maximum heart dose was recorded with DIBH vs FB; no significant difference was observed in other heart and left anterior descending coronary artery parameters. The median reduction in right lung mean dose was 2.8Gy for DIBH vs FB plans (IQR 1.6, 3.6) (p = 0.001); significant median reductions of V5Gy, V20Gy, and V30Gy were all achieved with DIBH. Chest wall PTV coverage did not significantly differ between DIBH and FB plans; IMC dosimetric coverage improved with use of DIBH (V47.5Gy, V45Gy, V42Gy). DIBH reduced OAR dose in right-sided PMRT + IMC patients. A novel finding was that DIBH decreased RCA dose. Heart and right lung dose were also decreased with DIBH, whilst optimally dosed PTVs were maintained.