MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circimaging.115.004956

Медицинская библиотека · Circulation. Cardiovascular imaging · 2016

Prognostic Benefit of Cardiac Magnetic Resonance Over Transthoracic Echocardiography for the Assessment of Ischemic and Nonischemic Dilated Cardiomyopathy Patients Referred for the Evaluation of Primary Prevention Implantable Cardioverter-Defibrillator Therapy.

Pontone Gianluca, Guaricci Andrea I, Andreini Daniele, Solbiati Anna, Guglielmo Marco, Mushtaq Saima, Baggiano Andrea, Beltrama Virginia, Fusini Laura, Rota Cristina, Segurini Chiara, Conte Edoardo, Gripari Paola, Dello Russo Antonio, Moltrasio Massimo, Tundo Fabrizio, Lombardi Federico, Muscogiuri Giuseppe, Lorenzoni Valentina, Tondo Claudio, Agostoni Piergiuseppe, Bartorelli Antonio L, Pepi Mauro

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study was to determine the prognostic benefit of cardiac magnetic resonance (CMR) over transthoracic echocardiography (TTE) in ischemic cardiomyopathy and nonischemic dilated cardiomyopathy patients evaluated for primary prevention implantable cardioverter-defibrillator therapy.

METHODS AND

RESULTS

We enrolled 409 consecutive ischemic and dilated cardiomyopathy patients (mean age: 64±12 years; 331 men). All patients underwent TTE and CMR, and left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricle ejection fraction (LVEF) were evaluated. In addition, late gadolinium enhancement was also assessed. All patients were followed up for major adverse cardiac events (MACE) defined as a composite end point of long runs of nonsustained ventricular tachycardia, sustained ventricular tachycardia, aborted sudden cardiac death, or sudden cardiac death. The median follow-up was 545 days. CMR showed higher left ventricle end-diastolic volume (mean difference: 43±22.5 mL), higher left ventricle end-systolic volume (mean difference: 34±20.5 mL), and lower LVEF (mean difference: -4.9±10%) as compared to TTE (P<0.01). MACE occurred in 103 (25%) patients. Patients experiencing MACE showed higher left ventricle end-diastolic volume, higher left ventricle end-systolic volume, and lower LVEF with both imaging modalities and higher late gadolinium enhancement per-patient prevalence as compared to patients without MACE. At multivariable analysis, CMR-LVEF ≤35% (hazard ratio=2.18 [1.3-3.8]) and the presence of late gadolinium enhancement (hazard ratio=2.2 [1.4-3.6]) were independently associated with MACE (P<0.01). A model based on CMR-LVEF ≤35% or CMR-LVEF ≤35% plus late gadolinium enhancement detection showed a higher performance in the prediction of MACE as compared to TTE-LVEF resulting in net reclassification improvement of 0.468 (95% confidence interval, 0.283-0.654; P<0.001) and 0.413 (95% confidence interval, 0.23-0.63; P<0.001), respectively.

CONCLUSIONS

CMR provides additional prognostic stratification as compared to TTE, which may have direct impact on the indication of implantable cardioverter-defibrillator implantation.

Для цитирования: Pontone Gianluca, Guaricci Andrea I, Andreini Daniele, Solbiati Anna, Guglielmo Marco, Mushtaq Saima, Baggiano Andrea, Beltrama Virginia, Fusini Laura, Rota Cristina, Segurini Chiara, Conte Edoardo, Gripari Paola, Dello Russo Antonio, Moltrasio Massimo, Tundo Fabrizio, Lombardi Federico, Muscogiuri Giuseppe, Lorenzoni Valentina, Tondo Claudio, Agostoni Piergiuseppe, Bartorelli Antonio L, Pepi Mauro. Prognostic Benefit of Cardiac Magnetic Resonance Over Transthoracic Echocardiography for the Assessment of Ischemic and Nonischemic Dilated Cardiomyopathy Patients Referred for the Evaluation of Primary Prevention Implantable Cardioverter-Defibrillator Therapy.. Circulation. Cardiovascular imaging. 2016. DOI: 10.1161/circimaging.115.004956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.