Ultrasound assessment of endotracheal tube depth in neonates: a prospective feasibility study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Levkovitz Orly, Schujovitzky Dana, Stackievicz Rodica, Fayoux Pierre, Morag Iris, Litmanovitz Ita, Arnon Shmuel, Bauer Sofia

Аннотация

OBJECTIVE: To examine the reliability of a novel ultrasound (US) method for assessment of endotracheal tube (ETT) position in neonates.

DESIGN: Prospective, observational, single-centre, feasibility study.

SETTING: Level III neonatal intensive care unit.

PATIENTS: Term and preterm neonates requiring endotracheal intubation.

INTERVENTION: US measurement of the ETT tip to right pulmonary artery (RPA) distance was used to determine ETT position according to one-fourth to three-fourths estimated tracheal length for weight. US demonstration of pleural sliding and diaphragmatic movement was also assessed. Chest radiography (CXR) was performed following each intubation.

MAIN OUTCOME MEASURES: Agreement between US assessment of ETT tip position and CXR served as the gold standard. Sensitivity, specificity, positive and negative predictive values for each US method and correlation between ETT tip to RPA distance on US, and ETT tip to carina distance on CXR were assessed.

RESULTS: Forty-two US studies were performed on 33 intubated neonates. US evaluation of ETT-RPA distance identified 100% of ETTs positioned correctly: 77% deep and 80% high, demonstrating strong agreement with CXR (kappa=0.822). Sensitivity was 78%, specificity 100%, positive predictive value 100% and negative predictive value 86%. US ETT-RPA distance strongly correlated with CXR ETT-carina distance (r=0.826). No significant agreement was found between CXR and US assessment of pleural sliding and diaphragmatic movement. No adverse events were encountered during US scans.

CONCLUSION: US evaluation of ETT-RPA distance demonstrated excellent accuracy for determining ETT position in neonates compared with CXR. More research is needed to support its feasibility in clinical settings.