Comparison of tipless and helical baskets in an in vitro ureteral model.

Lukasewycz Stephen, Hoffman Nathan, Botnaru Andrei, Deka P M, Monga Manoj

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare the rapidity of stone capture and removal by six tipless and four helical baskets in a ureteral model. Expeditious ureteral stone extraction is reliant on the basket size, configuration, and radial dilation force.

METHODS

A 5-mm feline calculus was placed in a simulated model of the human ureter at a distance of 7.5 cm from the orifice, and saline irrigant instilled. A 6/7.5F Wolf semirigid ureteroscope was used for access and visualization of the stone. Operators were randomized to start stone extraction with 1 of 10 stone baskets, and three extraction attempts were conducted with each device. Six experienced operators tested each device. The tipless baskets tested were the ACMI Sur-Catch NT 3.0F, Bard Dimension 3.0F, Boston Scientific Zerotip 3.0F, Cook N-Circle 3.0F, Cook Delta 2.4F, and Sacred Heart Halo 1.9F. The helical baskets tested were the Cook N-Force 3.2F, Microvasive Gemini 3.0F, ACMI Sur-Catch Helical 3.0F, and Sacred Heart Hercules 3.0F. The time to extraction in seconds was recorded.

RESULTS

No statistically significant difference was observed between the tipless (14 +/- 7 seconds) or helical (12.8 +/- 6.6 seconds, P = 0.21) basket groups. All baskets were able to retrieve the ureteral stones successfully. The most efficient basket was the Cook N-Circle with an average time of 8.7 seconds to stone extraction compared with the least efficient basket, the ACMI Sur-Catch NT, at 15.8 seconds.

CONCLUSIONS

The Cook N-Circle basket provided the most expeditious means to stone extraction in a ureteral model.

Для цитирования: Lukasewycz Stephen, Hoffman Nathan, Botnaru Andrei, Deka P M, Monga Manoj. Comparison of tipless and helical baskets in an in vitro ureteral model.. Urology. 2004. DOI: 10.1016/j.urology.2004.04.063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.