Laser stapedotomy minus prosthesis: long-term follow-up.
Аннотация
OBJECTIVE
To evaluate long-term hearing results following laser stapedotomy minus prosthesis (laser STAMP).
STUDY
DESIGN
Case series with chart review.
SETTING
Otologic referral center.
SUBJECTS AND
METHODS
From April 1995 to April 2009, 74 adult patients (77 ears; consecutive cases) underwent primary laser STAMP for otosclerosis limited to the fissula ante fenestram. Pure-tone air, bone conduction thresholds, and word discrimination scores were obtained preoperatively, 1 month postoperatively, and yearly thereafter.
RESULTS
One-year minimum follow-up data were available for 43 patients (44 ears; nonconsecutive cases). The average air-bone gap (ABG) was closed from a mean of 23 dB to 6 dB at 6 weeks postoperatively. At a median of 33 (lower quartile, 20; upper quartile 46; range, 12-140) months postoperatively,the mean ABG was 7 dB, indicating little evidence of refixation. Seven of 77 patients (9%) underwent revision surgery with stapedotomy and placement of prosthesis with good results. Four patients (5%) were revised within 1 year for other problems unrelated to stapes refixation. Refixation was noted in 3 patients (4%) undergoing revision surgery. Two of these patients (3%) were revised within 1 year, and 1 patient (1%)was revised after 12 years.
CONCLUSIONS
The laser STAMP is a minimally invasive procedure resulting in stable long-term hearing improvement in those patients available for long-term follow-up. Success depends on proper candidate selection of patients with accessible anatomy and minimal otosclerosis confined to the fissula ante fenestram. Advantages of this procedure include preservation of stapes anatomy and stable long-term, high-frequency hearing improvement.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.