Three-year data from the XIENCE V INDIA study: safety and efficacy of XIENCE V in 1000 real world Indian patients.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Seth Ashok, Patel Tejas M, Stuteville Marrianne, Kumar Ravindra, Mullasari Ajit S, Kaul Upendra, Mathew Rony, Sreenivas Kumar A, Ying Shih-Wa, Sudhir Krishnankutty
Аннотация
BACKGROUND: Cardiovascular disease in Asia has reached epidemic proportions in recent years. Use of drug eluting stents in Asians has rapidly expanded with varying penetration rates across different countries. The XIENCE V INDIA Study included 'real world' patients who underwent XIENCE V stent implantation to assess short and intermediate term outcomes in Indian patients with diverse risk factors.
OBJECTIVE: To evaluate 3-year clinical outcomes in a cohort of 'real world' Indian patients with CAD being treated with XIENCE V Everolimus Eluting Coronary Stent System.
METHODS: 1000 patients were enrolled from 18 sites in India between June 2008 and March 2009. Patients were included if their index procedures were completed using only XIENCE V. There were no clinical or angiographic exclusions. An independent Clinical Events Committee adjudicated all endpoint-related events. The primary endpoint was stent thrombosis rate annually through to 3 years as defined by the Academic Research Consortium criteria. The co-primary endpoint was the composite rate of cardiac death and myocardial infarction at 1 year.
RESULTS: At 1-year the primary endpoint of definite/probable stent thrombosis rate was 0.51%. No additional very late stent thrombosis was reported through a 3-year follow up. The composite endpoint of cardiac death and any myocardial infarction was 1.9%, 2.7% and 3.1% at 1, 2 and 3 years respectively.
CONCLUSION: Despite the high risk population of coronary artery disease, the use of XIENCE V in 'real world' Indian patients was associated with very low clinical event rates upto three years of follow up.
OBJECTIVE: To evaluate 3-year clinical outcomes in a cohort of 'real world' Indian patients with CAD being treated with XIENCE V Everolimus Eluting Coronary Stent System.
METHODS: 1000 patients were enrolled from 18 sites in India between June 2008 and March 2009. Patients were included if their index procedures were completed using only XIENCE V. There were no clinical or angiographic exclusions. An independent Clinical Events Committee adjudicated all endpoint-related events. The primary endpoint was stent thrombosis rate annually through to 3 years as defined by the Academic Research Consortium criteria. The co-primary endpoint was the composite rate of cardiac death and myocardial infarction at 1 year.
RESULTS: At 1-year the primary endpoint of definite/probable stent thrombosis rate was 0.51%. No additional very late stent thrombosis was reported through a 3-year follow up. The composite endpoint of cardiac death and any myocardial infarction was 1.9%, 2.7% and 3.1% at 1, 2 and 3 years respectively.
CONCLUSION: Despite the high risk population of coronary artery disease, the use of XIENCE V in 'real world' Indian patients was associated with very low clinical event rates upto three years of follow up.
Предметные рубрики MeSH
Antineoplastic AgentsCoronary AngiographyCoronary Artery DiseaseDrug-Eluting StentsEverolimusFemaleFollow-Up StudiesHumansImmunosuppressive AgentsIncidenceIndiaKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPostoperative ComplicationsPrognosisProspective StudiesProsthesis DesignRisk AssessmentRisk FactorsSirolimusSurvival RateTime FactorsTreatment Outcome