MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12435

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2014

Chronic kidney disease and implantable cardioverter defibrillator related complications: 16 years of experience.

Buiten Maurits S, DE Bie Mihály K, VAN DER Heijden Aafke C, Rotmans Joris I, Bootsma Marianne, Marc Groeneveld J H, Wolterbeek Ron, Rabelink Ton J, Jukema J Wouter, Schalij Martin J, VAN Erven Lieselot

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Implantable cardioverter defibrillator (ICD) implantation has become an accepted therapy for the prevention of sudden cardiac death. However, serious comorbidities such as chronic kidney disease (CKD) are influencing the beneficial effects of ICD therapy. In this study, the association between kidney function and the occurrence of ICD related complications was assessed.

METHODS

All patients receiving an ICD or cardiac resynchronization therapy-defibrillator between 1996 and 2012 were included. Renal function was categorized as: glomerular filtration rate (GFR) >90, GFR 30-90 or GFR <30 mL/min/1.73 m(2) . Registered complications were pocket hematoma, pneumothorax, lead complications, and device infection.

RESULTS

In 3,147 device recipients, 236 patients (7.5%) suffered from at least 1 complication. Patients with a GFR <30 (n = 110) had a higher event rate for hematoma, pneumothorax, and infection. These patients were older, had a higher incidence of hypertension, diabetes, and a lower body mass index (BMI; P < 0.05). After correcting for these risk factors, hematoma remained independently associated with a GFR <30 mL/min (OR 2.7, CI: 1.05-6.9, P = 0.04). Device infection, pneumothorax, and lead complications were not independently associated with a GFR <30 mL/min/1.73 m(2) .

CONCLUSIONS

Patients with CKD suffered from more ICD related complications than patients without kidney disease. This was partially associated with kidney dysfunction itself as was the case with the occurrence of hematoma. However, the high burden of risk factors associated with device complications in patients with renal disease played an important role as well.

Для цитирования: Buiten Maurits S, DE Bie Mihály K, VAN DER Heijden Aafke C, Rotmans Joris I, Bootsma Marianne, Marc Groeneveld J H, Wolterbeek Ron, Rabelink Ton J, Jukema J Wouter, Schalij Martin J, VAN Erven Lieselot. Chronic kidney disease and implantable cardioverter defibrillator related complications: 16 years of experience.. Journal of cardiovascular electrophysiology. 2014. DOI: 10.1111/jce.12435.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.